{"id":3327,"date":"2023-04-11T15:51:14","date_gmt":"2023-04-11T13:51:14","guid":{"rendered":"https:\/\/wp.delphin.de\/?post_type=loesung&#038;p=3327"},"modified":"2025-07-09T11:11:52","modified_gmt":"2025-07-09T09:11:52","slug":"pump-test-stands","status":"publish","type":"loesung","link":"https:\/\/www.delphin.de\/en\/loesungen\/pruefstaende-automatisierung\/pumpenpruefstaende\/","title":{"rendered":"Pump test stands"},"content":{"rendered":"<div class=\"gb-container gb-container-25a1a31e gb-container-00a24a60\">\n\n<h2 class=\"gb-headline gb-headline-9b087ccf gb-headline-text gb-headline-deab2af6\">Assured performance and high quality - with state-of-the-art measurement technology for pump test benches<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pump test benches are indispensable systems for the precise analysis and optimization of pump performance in a wide range of applications - from laboratory environments to heavy industry. They enable realistic tests under defined conditions and provide reliable measurement data for development, production, quality assurance and maintenance. With state-of-the-art measurement and automation technology, they help to increase operational reliability, avoid failures and shorten development cycles.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-76787e54\">\n\n<h2 class=\"gb-headline gb-headline-06ae1e68 gb-headline-text\">What advantages does a solution for pump test benches with Delphin offer you?<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>Long-term stable systems with secure data archiving: <\/strong>Ideal for service life tests and endurance tests.<\/li>\n\n\n\n<li><strong>Reliable condition monitoring:<\/strong> Limit value monitoring and automated alarms significantly increase operational safety.<\/li>\n\n\n\n<li><strong>Flexible test specimen control<\/strong>Control of the test specimens via analog, digital and PWM outputs - for comprehensive test automation.<\/li>\n\n\n\n<li><strong>Cross-industry use<\/strong>Suitable for laboratory applications, research, series production and quality assurance.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>High-resolution measurement: <\/strong>Up to 100 kHz sampling rate for precise analysis of dynamic processes.<\/li>\n\n\n\n<li><strong>Universal sensor connections: <\/strong>Supports mA, mV, Pt100, thermocouples and much more. - Maximum flexibility in signal acquisition.<\/li>\n\n\n\n<li><strong>Limit value monitoring &amp; alarming: <\/strong>Early fault detection and automatic shutdown in the event of faults.<\/li>\n\n\n\n<li><strong>Robust, low-maintenance hardware: <\/strong>For continuous operation in industrial environments - high availability and low operating costs.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div>\n\n<div class=\"gb-container gb-container-7847595c gb-container-00a24a60\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-752153cf\">\n<div class=\"gb-grid-column gb-grid-column-a98c2238\"><div class=\"gb-container gb-container-a98c2238\"><div class=\"gb-inside-container\"><\/div><\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-2fbda409\"><div class=\"gb-container gb-container-2fbda409\"><div class=\"gb-inside-container\">\n\n<p class=\"gb-headline gb-headline-8db5b690 gb-headline-text gb-headline-deab2af6\"><strong>Pump test benches are an indispensable tool for the development, production and maintenance of pumps. Typical areas of application are<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Endurance tests<\/li>\n\n\n\n<li>Speed monitoring by means of vibration measurement<\/li>\n\n\n\n<li>Characteristic curve determination<\/li>\n\n\n\n<li>Map determination, delivery head via volume flow<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Idle tests<\/li>\n\n\n\n<li>Heating test<\/li>\n\n\n\n<li>Efficiency determination<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div><\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-5a79da51\">\n<div class=\"gb-container gb-container-464d05fe gb-container-inner-shadow\">\n\n<p class=\"gb-headline gb-headline-dbfce4e4 gb-headline-text gb-headline-topline\">Practical example of a pump test stand<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Precise and versatile testing of hydraulic pumps<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A leading manufacturer of hydraulic pumps has implemented three performance-differentiated test benches for tests during development - graded to performance classes of 30 kW, 90 kW and 250 kW. The aim was to efficiently test and evaluate both individual components and complete systems under realistic conditions. In order to meet the high requirements for measurement speed and data diversity, the company decided to use the <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/pc-supported-measurement-technology-expert-key\/\">Expert Key C-Series <\/a>\u00a0for control cabinet integration. These data acquisition devices offer a sampling rate of up to 100 kHz and therefore also enable the analysis of fast, transient processes - a decisive advantage when testing dynamic systems such as hydraulic pumps. Visualization and evaluation are carried out via the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/\" data-type=\"produkt\" data-id=\"1354\">ProfiSignal software<\/a>which allows the intuitive creation of individual test sequences and evaluation functions - without any programming knowledge. Test engineers can react flexibly to new test requirements and configure their own test sequences and user interfaces independently. Another focus was on seamless Office integration: with just a few clicks, measurement results can be exported as ASCII or Excel files or transferred as high-resolution, vector-based graphics directly into Word documents for test reports. This saves time, reduces manual transmission errors and simplifies documentation considerably.<\/p>\n\n<\/div>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>For reliable testing of e.g. miniature metering pumps, vacuum or large pumps<\/p>","protected":false},"author":6,"featured_media":5501,"parent":1080,"menu_order":16,"template":"","format":"standard","categories":[],"tags":[],"class_list":["post-3327","loesung","type-loesung","status-publish","format-standard","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/loesung\/3327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/loesung"}],"about":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/types\/loesung"}],"author":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/users\/6"}],"version-history":[{"count":5,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/loesung\/3327\/revisions"}],"predecessor-version":[{"id":16035,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/loesung\/3327\/revisions\/16035"}],"up":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/loesung\/1080"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media\/5501"}],"wp:attachment":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media?parent=3327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/categories?post=3327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/tags?post=3327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}