{"id":3609,"date":"2022-06-12T13:52:59","date_gmt":"2022-06-12T11:52:59","guid":{"rendered":"https:\/\/wp.delphin.de\/?post_type=fachinformationen&#038;p=3609"},"modified":"2024-09-17T14:47:07","modified_gmt":"2024-09-17T12:47:07","slug":"decentralized-collection-so-that-everything-runs-smoothly-in-the-pumping-station","status":"publish","type":"post","link":"https:\/\/www.delphin.de\/en\/dezentrale-erfassung-damit-es-im-pumpwerk-rund-laeuft\/","title":{"rendered":"Decentralized recording with the Delphin Loggito logger - so that everything runs smoothly in the pumping station"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>The decentralized recording and autonomous monitoring of distributed measuring points, including networking options, is becoming an increasingly important component for keeping an eye on the status of systems and machines, even remotely. The Ennepetal municipal sewage company, which relies on the compact Loggito loggers from Delphin Technology AG to monitor its pumping stations, was faced with this task.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stadtentw\u00e4sserungsbetriebe Ennepetal operates 18 pumping stations spread across the entire city. The fill levels of the pump sumps and the operating status of the pumps are monitored at the respective stations. Two pumps at a time are controlled via a programmable logic controller (PLC) in alternating operation in order to be able to optimally regulate the inflows and outflows in the overall system. This serves to ensure the operational safety of the sewer systems and must be monitored around the clock in order to be able to react as quickly as possible in the event of faults caused by blockages or problems with the pumps, for example. Until now, the relevant data was transmitted to the service technicians via the 3G mobile network. Due to the planned shutdown of 3G and the update to LTE (4G), the measurement data acquisition was upgraded to a future-proof level with the help of the compact Loggito loggers from Delphin Technology AG.<\/p>\n\n\n<div class=\"gb-container gb-container-c7bf4a10 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">AUTONOMOUS MEASUREMENT DATA ACQUISITION DECENTRALIZED AT THE RESPECTIVE PUMPING STATION<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To ensure autonomous measurement data acquisition, a data logger was initially installed in each of the 18 pumping stations. With the help of the high-precision and universally usable sensor inputs, the required sensors for fill levels, current consumption, operating data and fault messages could be connected without any problems. In combination with the internal monitoring and calculation channels as well as the operating hours counters, the recorded process data not only provides information on the current status of the pumping stations, but also on the expected time for maintenance. This enables predictive maintenance of the pumping stations. The pumps can be optimally and predictively maintained and downtimes can be prevented. All signals are pre-processed, monitored and stored in the Loggito logger before being forwarded to the central data server.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-9d1654e3 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">INTERNAL DATA STORAGE ENSURES GREATER SECURITY<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The PC-independent operation of the data logger with its internal data memory also ensures a high level of data security with regard to remote data transmission. In the event of a temporary failure of the mobile phone connection or a fault on the central server, all recorded data can be stored in the internal data memory. As soon as the mobile network and the server are available again, remote data transmission to the server continues fully automatically and without user intervention. This means that no data is lost and the measurement database on the server is completely filled.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-90d4c05b gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">MONITORING @ the edge<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The autonomous pre-processing, monitoring and analysis of all signals with the Loggito loggers at the respective pumping station enables independent monitoring including automatic shutdown functions. Even if there is temporarily no radio connection to the respective pumping station, such functions are guaranteed at all times thanks to the self-sufficient mode of operation. If, for example, the limit value for the storage temperature or the power consumption of a pump is exceeded, the system can be switched off using the digital outputs of the Loggito logger.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-756618d0 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">TRANSMISSION OF MEASUREMENT DATA TO THE CENTRAL SERVER<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to the Loggito loggers, LTE routers with powerful antennas were also installed on site at the pumping stations in order to send the decentrally recorded measurement data to the central server via LTE.<\/p>\n\n<\/div>\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2022\/06\/Stadtgebiet-Pumpstationen.png\" alt=\"\" class=\"wp-image-12765\" style=\"width:700px\" title=\"\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>The pumping stations distributed throughout the city communicate with the central data center via LTE.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The routers are equipped with an automatic restart, which re-establishes the connection and ensures remote data transmission in the event of an error in the connection setup or the availability of the VPN gateway. The Delphin Data Center (DDC) and the ProfiSignal 20 server are installed on the server and are responsible for central measurement data management and user administration. All data collected from the 18 pumping stations is networked, centrally stored, monitored and analyzed on the server. The measurement data is archived in a valid and traceable manner and can be retrieved at any time with access within seconds, whether on the network, via PC or mobile via smartphone or tablet. All pumping stations can be centrally networked with each other. This also enables a comparison and in-depth analysis of the individual pumping stations. The transmission of the measurement data to end devices of the city of Ennepetal is realized within a secure network via VPN tunnel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The connection to the individual data loggers and the status of each measuring point are also monitored centrally and automatic e-mail alerts are sent. As the DataService runs on the server as a Windows service, it is independent of a user login in the operating system and the alarm function via e-mail is available at all times. Employees can access the data center via OpenVPN Client. Smartphones and tablets can also access the PS20 server and the Data Center and call up the visualization via the OpenVPN app and PS20 client app. The required PS20 app can be downloaded free of charge for both iOS and Android devices from the respective app store. <\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"570\" height=\"343\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2022\/06\/Online-und-Offlinewerte-der-Pumpwerke-e1703061307530.jpg\" alt=\"\" class=\"wp-image-12766\" style=\"width:650px\" title=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2022\/06\/Online-und-Offlinewerte-der-Pumpwerke-e1703061307530.jpg 570w, https:\/\/www.delphin.de\/wp-content\/uploads\/2022\/06\/Online-und-Offlinewerte-der-Pumpwerke-e1703061307530-300x181.jpg 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2022\/06\/Online-und-Offlinewerte-der-Pumpwerke-e1703061307530-18x12.jpg 18w\" sizes=\"(max-width: 570px) 100vw, 570px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Direct remote access to the online and offline values of the pumping stations<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Another advantage of remote access to all pumping stations is that not only the visualization of the measured values, but also the configuration of the Loggito Logger devices can be carried out remotely. With the help of user administration, it is possible to clearly define which user groups can make changes to the basic system and the device configuration and which user groups only have read-only access to the system. This enables service technicians, for example, to make adjustments to limit values or the monitoring and storage of various parameters without having to spend time and effort traveling to the respective pumping station each time. This increases flexibility and saves resources at the same time.<\/p>\n\n\n<div class=\"gb-container gb-container-c4a6adde gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">VISUALIZATION OF THE MEASUREMENT DATA FOR THE SERVER TECHNICIANS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The ProfiSignal 20 Basic software is the front end of the monitoring system and offers an interactive user interface. The platform-independent complete software for the visualization and analysis of the recorded measurement data is installed in the control room as a desktop application and can also be accessed at any time via the PS20 app on the service technicians' mobile devices. The measured values and their progression over time are displayed in measurement curves on clear dashboards. These trends make it quick and easy to view the measured values historically. An overview chart shows the status based on collective alarms for all 18 monitored pumping stations. The alarm list is also displayed in tabular form on a separate chart. This means that both the service technician on the road and the office staff have access to all measurement data at all times.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-b1f48e97 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">OUTLOOK FOR THE FUTURE<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The fact that the Delphin DataCenter (DDC) bundles the data from all 18 Loggito loggers on the central server enables further expansion options for the monitoring system. It is conceivable that the pumping stations could communicate with each other, i.e. the Loggito loggers could exchange and share their data via the DataService. For example, the fill level of a downstream shaft could be queried before a pumping command is issued in the upstream structure in order to prevent overflows. The versatile interfaces, such as Modbus TCP and OPC UA, could also be used to integrate other peripherals such as frequency converters or power meters at the pumping stations into the Delphin monitoring system. Ultimately, the pumps could also be controlled via a measurement data logger from Delphin Technology AG and replace the controllers currently in use. The future expansion stages of the system therefore remain exciting.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-8bc1f66e gb-container-00a24a60\">\n\n<p class=\"wp-block-paragraph\"><em>Pictures: Delphin<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">COMPANY<br>Delphin Technology AG<br>Lustheide 81 , 51427 Bergisch Gladbach<br>Phone 02204 \/ 97685-0<br>Mail: info@delphin.de<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AUTHOR<br>Jan Tippner, B.Eng., Head of Sales, <br>Delphin Technology AG, Bergisch Gladbach<\/p>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The decentralized recording and autonomous monitoring of distributed measuring points, including networking options, is becoming an increasingly important component for keeping an eye on the status of systems and machines, even remotely. The Ennepetal municipal sewage company has now also faced this challenge and has opted for the compact Loggito loggers from Delphin Technology to monitor its pumping stations. <a title=\"Decentralized recording with the Delphin Loggito logger - so that everything runs smoothly in the pumping station\" class=\"read-more\" href=\"https:\/\/www.delphin.de\/en\/dezentrale-erfassung-damit-es-im-pumpwerk-rund-laeuft\/\" aria-label=\"Read more about Decentralized logging with the Delphin Loggito logger - so that everything runs smoothly in the pumping station\">Read more<\/a><\/p>","protected":false},"author":6,"featured_media":12767,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[101,1,110,103],"tags":[],"blog-kategorie":[78],"intern":[90],"class_list":["post-3609","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-delphin-data-center","category-hardware","category-loggito-hardware","category-profi-signal-20","blog-kategorie-fachbeitraege","intern-load-post"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/posts\/3609","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/comments?post=3609"}],"version-history":[{"count":3,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/posts\/3609\/revisions"}],"predecessor-version":[{"id":12917,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/posts\/3609\/revisions\/12917"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media\/12767"}],"wp:attachment":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media?parent=3609"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/categories?post=3609"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/tags?post=3609"},{"taxonomy":"blog-kategorie","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/blog-kategorie?post=3609"},{"taxonomy":"intern","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/intern?post=3609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}