{"id":1247,"date":"2023-03-08T08:47:56","date_gmt":"2023-03-08T07:47:56","guid":{"rendered":"https:\/\/wp.delphin.de\/?post_type=produkt&#038;p=1247"},"modified":"2026-01-16T15:42:43","modified_gmt":"2026-01-16T14:42:43","slug":"transient-recorder-expert-transient","status":"publish","type":"produkt","link":"https:\/\/www.delphin.de\/en\/produkte\/messgeraete-pruefgeraete\/transientenrekorder-expert-transient\/","title":{"rendered":"Expert Transient"},"content":{"rendered":"<div class=\"gb-container gb-container-1713c3d5 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\"><strong>Expert Transient data recorder<\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading has-38-font-size\">Reliable data acquisition for clear decisions<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Whether analyzing fault events, in test mode or in quality control - with the Expert Transient transient recorder you always have an overview. The system records analog and digital signals synchronously and with high accuracy, so that even the smallest details are reliably documented.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For you, this means: maximum data security through parallel internal and external storage, flexible scalability from a few to over 100 measurement channels and convenient visualization and analysis of your measurement data with modern measurement technology software.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This allows you to transform complex measurement tasks into clear information - and create a secure basis for quick and well-founded decisions.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-5fe21863 gb-container-inner-shadow\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-210d8a23\">\n<div class=\"gb-grid-column gb-grid-column-94019e0a\"><div class=\"gb-container gb-container-94019e0a\"><div class=\"gb-inside-container\">\n\n<h3 class=\"wp-block-heading\">Product highlights<\/h3>\n\n\n\n<ul class=\"wp-block-list list has-medium-font-size\">\n<li>Transient and periodic signals are detected with maximum precision<\/li>\n\n\n\n<li>Flexible measuring modes - triggered or permanent - enable up to 800 kS total sampling rate<\/li>\n\n\n\n<li>Fast results thanks to powerful online analysis functions<\/li>\n\n\n\n<li>Synchronous expansion with additional analog and digital inputs<\/li>\n\n\n\n<li>Self-sufficient operation with integrated long-term memory for maximum data security<\/li>\n\n\n\n<li>Compact and robust design for use in all conditions<\/li>\n<\/ul>\n\n<\/div><\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-24cd414b\"><div class=\"gb-container gb-container-24cd414b\"><div class=\"gb-inside-container\">\n\n<figure class=\"gb-block-image gb-block-image-3f0aecc9\"><img decoding=\"async\" width=\"1100\" height=\"1200\" class=\"gb-image gb-image-3f0aecc9\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-transient-250220.jpg\" alt=\"expert transient product highlights\" title=\"delphin-website-product-hilights-expert-transient-250220\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-transient-250220.jpg 1100w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-transient-250220-275x300.jpg 275w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-transient-250220-939x1024.jpg 939w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-transient-250220-768x838.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-transient-250220-11x12.jpg 11w\" sizes=\"(max-width: 1100px) 100vw, 1100px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-7295ddc2\">\n\n<a class=\"gb-button gb-button-793cd39f gb-button-text gb-button-standard\" href=\"https:\/\/www.youtube.com\/watch?v=XDIDXvvxjtE&amp;list=PLpIbw-HtoMuzkuT7u624yctwKaFNEcSqu&amp;index=2\" target=\"_blank\" rel=\"noopener noreferrer\">Watch video<\/a>\n\n\n\n<a class=\"gb-button gb-button-cdfc5b30 gb-button-text gb-button-standard\" href=\"https:\/\/www.delphin.de\/en\/transient-measurement-data-acquisition\/\" target=\"_blank\" rel=\"noopener noreferrer\">More in the blog<\/a>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-670448aa gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">I\/Os and interfaces<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The clear display of all inputs and outputs as well as communication interfaces enables efficient system integration and uncomplicated commissioning.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"delphin-io grid-3x2 has-image\"><div class=\"delphin-io__col col-left\"><div class=\"delphin-io__box area-inputs\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Input signals<\/h3><div class=\"delphin-io__content\"><ul>\n<li>Voltage\/Currents<\/li>\n<li>Digital input<\/li>\n<li>Frequencies<\/li>\n<\/ul>\n<\/div><\/div><div class=\"delphin-io__box area-outputs\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Output signals<\/h3><div class=\"delphin-io__content\"><ul>\n<li>Voltage\/Currents<\/li>\n<li>PWM<\/li>\n<li>Digital output<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div><div class=\"delphin-io__center area-center\"><figure class=\"delphin-io__figure\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/20250108_Expert_Transient_1-1024x683.jpg\" alt=\"Expert Transient Hardware\" title=\"\"><\/figure><h2 class=\"delphin-io__main-title\">Expert Transient<\/h2><\/div><div class=\"delphin-io__col col-right\"><div class=\"delphin-io__box area-interfaces\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Interfaces<\/h3><div class=\"delphin-io__content\"><ul>\n<li>LAN<\/li>\n<li>USB<\/li>\n<li>RS 232\/485<\/li>\n<\/ul>\n<\/div><\/div><div class=\"delphin-io__box area-protocols\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Protocols<\/h3><div class=\"delphin-io__content\"><ul>\n<li>PROFINET<\/li>\n<li>PROFIBUS<\/li>\n<li>CAN<\/li>\n<li>Modbus TCP<\/li>\n<li>Modbus RTU<\/li>\n<li>OPC UA<\/li>\n<li>OPC UA HA<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/section>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Here you will find an overview of the standard and optionally available <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/#interfaces-and-protocols\"><strong>Hardware interfaces and protocols.<\/strong><\/a> Find out more about the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/schnittstellen\/\"><strong>interface diversity<\/strong><\/a> our measurement technology software.<\/p>\n\n\n<div class=\"gb-container gb-container-4c28cd1a gb-container-00a24a60\">\n<div class=\"gb-container gb-container-a98c2238\"><\/div>\n\n<div class=\"gb-container gb-container-6d978ee7\">\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>Benefit from synchronous recording and high measurement accuracy with the transient recorder. Typical solutions with the Expert Transient are<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>High-speed acquisition of analog or digital signals<\/li>\n\n\n\n<li>Fault diagnostics on machines, systems and test stand<\/li>\n\n\n\n<li>Evaluation of pressure pluses \/ surges<\/li>\n\n\n\n<li>High-speed process monitoring and controller optimisation<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Crash, detonation and explosion experiments<\/li>\n\n\n\n<li>Shock and vibration measurement<\/li>\n\n\n\n<li>Material research and environmental simulation<\/li>\n\n\n\n<li>Test stand and lab experiments<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div>\n<\/div>\n\n<div id=\"functions\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Functions<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-535c75ca gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">Expert Transient - Full control over every signal<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Expert Transient records analog and digital measured values fully synchronously, enabling precise temporal analysis of event chains. Data is stored permanently or triggered - including the pre- and post-history of an incident.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>Everything in view - even with fast processes<\/strong> - Expert Transient records analog and digital signals fully synchronously with a sampling rate of up to 50 kHz per channel and 24-bit resolution. This means that even very short disturbances or fast signal progressions are precisely detected and reliably documented.<\/li>\n\n\n\n<li><strong>Flexibly measure what really counts<\/strong> - With permanent or triggered recording, the measurement strategy can be optimally adapted. Thanks to flexible trigger conditions, pre- and post-histories of events can be recorded precisely.<\/li>\n\n\n\n<li><strong>Precision and safety in every detail<\/strong> - Up to 16 galvanically isolated analog inputs and 4 synchronous digital inputs ensure exact reconstruction of event chains. The system can be expanded to more than 100 channels via the CAN interface - for maximum flexibility.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>Fast response in an emergency<\/strong> - Fast digital outputs are available if limit values are exceeded. In addition, alarms can be triggered automatically by e-mail or SMS - for immediate information and maximum safety.<\/li>\n\n\n\n<li><strong>Reliable data storage without compromise<\/strong> - All measured values are securely stored in the internal 32 GB memory or backed up in parallel on an external NAS. This means that no data is lost - even with long-term recordings.<\/li>\n\n\n\n<li><strong>Time synchronization for clear analyses<\/strong> - Measured values can be precisely synchronized via GPS, NTP or PTP. This allows even complex systems to be analyzed precisely and fault events to be tracked to the millisecond.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n<div class=\"gb-container gb-container-a92f0fef gb-container-00a24a60\">\n<div class=\"wp-block-image is-style-default\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"369\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-transient-loesbare-schraubklemmen-detail-breit-230419-1024x369.jpg\" alt=\"\" class=\"wp-image-4475\" style=\"width:1200px;height:undefinedpx\" title=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-transient-loesbare-schraubklemmen-detail-breit-230419-1024x369.jpg 1024w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-transient-loesbare-schraubklemmen-detail-breit-230419-300x108.jpg 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-transient-loesbare-schraubklemmen-detail-breit-230419-768x277.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-transient-loesbare-schraubklemmen-detail-breit-230419.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"gb-headline gb-headline-3b3786ea gb-headline-text gb-headline-p-small\"><em>Expert Transient - detachable screw terminal illustration<\/em><\/p>\n\n<\/div>\n<\/div>\n\n<div id=\"versions\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Versions<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Expert Transient - From compact to extended: design as required<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Expert Transient is available in versions with 4, 8, 12 or 16 analog inputs and 4 digital inputs and can be expanded to up to 100 channels via extensions. A 32 GB data memory is available for stand-alone use; alternatively, measured values can be stored in parallel on an external NAS with virtually unlimited capacity. The Expert Transient therefore offers maximum safety and flexibility both in the laboratory and in the field.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Inputs \/ Outputs<\/th><th>Type 4<\/th><th><strong>Type 8<\/strong><\/th><th>Type 12<\/th><th>Type 16<\/th><\/tr><\/thead><tbody><tr><td>Analog inputs (mV, mA)<\/td><td>4<\/td><td>8<\/td><td>12<\/td><td>16<\/td><\/tr><tr><td>Analog outputs (mV, mA)<\/td><td>4<\/td><td>4<\/td><td>4<\/td><td>4<\/td><\/tr><tr><td>Digital \/ Frequencies inputs<\/td><td>4<\/td><td>4<\/td><td>4<\/td><td>4<\/td><\/tr><tr><td>Digital outputs<\/td><td>8<\/td><td>8<\/td><td>8<\/td><td>8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Here you will find an overview of the standard and optionally available <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/#interfaces-and-protocols\"><strong>Hardware interfaces and protocols.<\/strong><\/a> Find out more about the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/schnittstellen\/\"><strong>interface diversity<\/strong><\/a> our measurement technology software.<\/p>\n\n\n<div id=\"technische-daten\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Technical specifications<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-908ba896 gb-container-00a24a60\">\n<div class=\"gb-container gb-container-f1836c22 del-accordion-preview gb-accordion\">\n<div class=\"gb-container gb-container-fe4b4821 gb-accordion__item\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3c1e3b88 gb-accordion__toggle\" id=\"gb-accordion-toggle-3c1e3b88\"><span class=\"gb-button-text\">All data overview<\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" ariahidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" ariahidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-8b8b1a0d\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-8b8b1a0d\">\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"translation-block\"><strong>Analog inputs<\/strong><\/td><td><strong>4, 8, 12 or <\/strong><strong>16<\/strong><\/td><\/tr><tr><td>Sampling rate, adjustable per channel<\/td><td>20 Hz .. 50 kHz<\/td><\/tr><tr><td>Usable signal range<\/td><td>DC .. 20 kHz<\/td><\/tr><tr><td>Voltage range<\/td><td>\u00b1 25 V<\/td><\/tr><tr><td>Current measuring range<\/td><td>0 .. 20 mA \/ 4 .. 20 mA \/ free<\/td><\/tr><tr><td>Signal conditioning, software switchable<\/td><td>None, AC coupling, IEPE<\/td><\/tr><tr><td>Resolution\/type ADC \/ input impedance<\/td><td>24 bit Sigma-Delta \/ 4 G\u03a9<\/td><\/tr><tr><td>Dielectric withstand voltage&nbsp;<\/td><td>\u00b1 100 VDC<\/td><\/tr><tr><td class=\"translation-block\">Galvanic isolation channel to channel \/ channel to system \/ PE<\/td><td>\u00b1 400 VDC<\/td><\/tr><tr><td>Measurement accuracy<\/td><td>0.5 mV + 0.008 % from measurement value<\/td><\/tr><tr><td><strong>Digital<br>inputs<\/strong><\/td><td><strong>4<\/strong><\/td><\/tr><tr><td>Input signal<\/td><td>low: 0 .. 1 V \/ high: 5 .. 100 VDC@3.5 mA<\/td><\/tr><tr><td class=\"translation-block\">Galvanic isolation channel to channel \/ channel to system \/ PE<\/td><td>\u00b1 400 VDC<\/td><\/tr><tr><td>Max. input frequency \/ min. pulse width<\/td><td>1 MHz \/ 500 ns<\/td><\/tr><tr><td><strong>Analog outputs<\/strong><\/td><td><strong>4<\/strong><\/td><\/tr><tr><td>Resolution<\/td><td>16 bit<\/td><\/tr><tr><td>Output ranges<\/td><td>0 .. 10 V \/ \u00b1 10 V \/ 0 .. 20 mA \/ 4 .. 20 mA \/ \u00b120 mA<\/td><\/tr><tr><td class=\"translation-block\">Galvanic isolation channel to channel \/ channel to system \/ PE<\/td><td>\u00b1 400 VDC<\/td><\/tr><tr><td>Min. load \/ max. burden<\/td><td>650 \u03a9<\/td><\/tr><tr><td><strong>Digital outputs<\/strong><\/td><td><strong>8<\/strong><\/td><\/tr><tr><td>Max. switching voltage \/ current \/ PWM<\/td><td>50 V \/ 2.5 A for 2 seconds, 250 mA continuous current \/ galvanically isolated \/ 5 Hz .. 10 kHz, up to 1:1000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Data storage<\/strong><\/td><\/tr><tr><td>Internal \/ external<\/td><td>32 GB (approx. 2,300 million measured values) \/ USB, NFS, CIFS, (S)FTP<\/td><\/tr><tr><td><strong>Signal comditioning functions<\/strong><\/td><\/tr><tr><td><strong>High-pass \/ low-pass \/ bandpass filter<\/strong><\/td><\/tr><tr><td>Cut-off frequency \/ filter order \/ filter characteristic<\/td><td>5 Hz .. 20 kHz \/ 4, 6, 8, 10 \/ incl. Butterworth<\/td><\/tr><tr><td><strong>Analysis<\/strong><\/td><\/tr><tr><td>Integrator \/ Differentiator<\/td><td>Single or double integrator \/ differentiator<\/td><\/tr><tr><td><strong>Characteristic values from time signal<\/strong><\/td><\/tr><tr><td><\/td><td>Maximum \/ minimum value, peak-to-peak value, arithm. average, TRMS, max, vect. sum, local min. \/ max. values<\/td><\/tr><tr><td><strong>Characteristic values on digital input<\/strong><\/td><\/tr><tr><td>Frequency<\/td><td>0.2 Hz .. 1 MHz<\/td><\/tr><tr><td>Counter<\/td><td>64 bit, UP-Down counter, quadratur decoder<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Interfaces<\/strong><\/td><\/tr><tr><td>Physical equipment COM 1 \/ COM 2<\/td><td>RS485, 9-pole sub-D socket, IEC 61158-2<\/td><\/tr><tr><td>Physical equipment COM 3<\/td><td>RS232, 9-pole sub-D-plugs<\/td><\/tr><tr><td>LAN<\/td><td>1 x 1000BASE-T<\/td><\/tr><tr><td>USB<\/td><td>Device 2.0 \/ Host 2.0 \/ low \/ high \/ full<\/td><\/tr><tr><td>PROFIBUS<\/td><td class=\"translation-block\">2 x PROFIBUS DPV1 \/ Slave max. 12 Mbit, also redundant according to PNO 2.212 V1.2, passive PROFIBUS sniffer<\/td><\/tr><tr><td>CAN \/ RS 232\/485<\/td><td>2 x CAN 2.0 \/ Modbus RTU Master &amp; Slave, SCPI, ASCII<\/td><\/tr><tr><td>TCP\/IP<\/td><td>Modbus TCP Server &amp; Client, OPC UA Server &amp; Client, OPC UA HA Server (optional), SMTP, NTP, PTP<\/td><\/tr><tr><td>PROFINET (TCP\/IP)<\/td><td>PROFINET RT Device, IO\/MRP\/LLDP, Conf Class B, RT Class 1, Netload Class III, I&amp;M 0,1,2,3,5, 2xRJ45 100MBit\/s full duplex<\/td><\/tr><tr><td><strong>General technical information<\/strong><\/td><\/tr><tr><td>Dimensions \/ weight<\/td><td>W 217 mm x H 88 mm x D 128 mm \/ 750 g<\/td><\/tr><tr><td>Fixing<\/td><td>Mounting rail DIN EN 60715 or screw mounting<\/td><\/tr><tr><td>Connecting terminals<\/td><td>Plug-in screw terminals, 96 terminals in 2 rows, max. 1.5 mm\u00b2<\/td><\/tr><tr><td>Temperature range<\/td><td>-20 .. 50 \u00b0C*<\/td><\/tr><tr><td>Humidity<\/td><td>max. 90 % relative humidity, non-condensing<\/td><\/tr><tr><td>Supply voltage<\/td><td>12 .. 24 V \/ \u00b1 10%<\/td><\/tr><tr><td>Power input<\/td><td>max. 20 W<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">* Sufficient air circulation in the control cabinet must be ensured.<br><em>Status: 20.02.2025<\/em><\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div id=\"software\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Software<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-41fd161a gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">Software interfaces<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern software interfaces make Expert Transient compatible with common industrial and IoT systems.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"delphin-softio grid-3x1\"><div class=\"softio-box softio-interfaces\" style=\"--box-bg:#FFFFFF;\"><h3 class=\"softio-title\">Interfaces<\/h3><div class=\"softio-content\"><ul>\n<li>OPC (Server\/Client)<\/li>\n<li>OPC UA (Server\/Client)<\/li>\n<li>OPC UA HA (Server)<\/li>\n<li>API<\/li>\n<li>Python<\/li>\n<li>SQL<\/li>\n<li>LabView<\/li>\n<li>Diadem<\/li>\n<li>Modbus TCP<\/li>\n<li>DasyLab<\/li>\n<\/ul>\n<\/div><\/div><div class=\"softio-box softio-dataservice\" style=\"--box-bg:#FFFFFF;\"><h3 class=\"softio-title\">DataService \/ Data Center<\/h3><\/div><div class=\"softio-hero\" style=\"--box-bg:#FFFFFF;\"><h2 class=\"softio-main-title\">Expert Transient<\/h2><figure class=\"softio-figure\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/20250108_Expert_Transient_1-1024x683.jpg\" alt=\"Expert Transient Hardware\" title=\"\"><\/figure><\/div><\/section>\n<\/div><\/div>\n\n<div class=\"gb-container gb-container-6432dff6 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading has-text-align-left\">Suitable software for Expert Transient<\/h2>\n\n\n<div class=\"produkt-tabs-block\" style=\"\">\n    <div class=\"produkt-tabs__container\"><div class=\"produkt-tabs\"><div class='produkt-tab activeTab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Go<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Basic<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Klicks<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal 20 Basic<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal 20 Go<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-300x225.png\" class=\"produkt-tab__img\" alt=\"Central measurement data management Delphin Date Canter\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-300x225.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-768x576.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-16x12.png 16w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025.png 987w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>Delphin Data Center<\/div><\/div><\/div><\/div><div class=\"produkt-details\"><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Go<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Data acquisition and analysis<\/h3><p class='produkt-detail__text'>Display and monitor measurement data live | Intuitive operation and easy handling without programming knowledge | Versatile diagram and analysis functions for various measurement data | Ready for data acquisition and analysis in just a few minutes<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-go\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-go-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Basic<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Operating and monitoring<\/h3><p class='produkt-detail__text'>Reliably record and save measurement data | Clearly display and evaluate measured values | Quickly set up and operate projects without programming effort | Ideal for individual measuring stations up to small measuring systems<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-basic\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-basic-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Klicks<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Automate and control<\/h3><p class='produkt-detail__text'>Monitor measurement data and control processes directly | Create automations simply by dragging and dropping | Suitable for complex test benches and automation tasks | Implement and adapt projects without programming knowledge<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-klicks\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-klicks-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal 20 Basic<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Visualisation and operation<\/h3><p class='produkt-detail__text'>Easily create your own visualizations for measurement data | Conveniently evaluate and log measurement and process data | Intuitive interface for efficient work without programming knowledge | Ideal for individual measuring stations through to complex monitoring solutions<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal-20\/profisignal-20-basic\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal20-basic-230329-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal 20 Go<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Data acquisition and saving<\/h3><p class='produkt-detail__text'>Display and monitor signals and processes in real time | Easy handling with no training required | Access to measurement data from PC, tablet or smartphone | Ready for many measurement and analysis tasks in just a few minutes<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal-20\/profisignal-20-go\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal20-go-230329-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>Delphin Data Center<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Central measurement data management<\/h3><p class='produkt-detail__text'>Central storage of operating, maintenance and process data | Cross-site real-time monitoring of machine and process statuses | Modular structure makes it easy to adapt to growing plant and process environments<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/delphin-data-center\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-ddc-230329-1-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><\/div><\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-c0f069fe gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">Software channels as extended functions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Realise and execute monitoring and automation tasks easily<\/strong>&nbsp;<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Our measuring and testing devices have extended functions, which are summarized under the term software channels. The online measurement data is offset against the software channels and then used for visualization, storage or control.\u00a0\u00a0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this way, entire programme sequences can be configured very simply and intuitively with the regulation and control function. These then run autonomously without PC support. This is how you use your data logger effectively, also as a monitoring device or PLC replacement.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The software channels enable functions such as limit value monitoring, integration or online calculation and are configured very easily. This means that even users who are not experts in programming can easily implement their own monitoring tasks or balancing independently in the unit.&nbsp;<\/p>\n\n\n\n<a class=\"gb-button gb-button-e5af81a4 gb-button-text gb-button-small\" href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/software-channels\/\" target=\"_blank\" rel=\"noopener noreferrer\">More information<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Intelligent data recorder for synchronous recording of transient and periodic events.<\/p>","protected":false},"author":3,"featured_media":15666,"parent":1168,"menu_order":4,"template":"","format":"standard","categories":[1,16],"tags":[],"class_list":["post-1247","produkt","type-produkt","status-publish","format-standard","has-post-thumbnail","hentry","category-hardware","category-datenlogger-messgeraete-steuerungen"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/types\/produkt"}],"author":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/users\/3"}],"version-history":[{"count":14,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1247\/revisions"}],"predecessor-version":[{"id":17046,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1247\/revisions\/17046"}],"up":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media\/15666"}],"wp:attachment":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media?parent=1247"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/categories?post=1247"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/tags?post=1247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}