{"id":1257,"date":"2023-03-08T08:49:56","date_gmt":"2023-03-08T07:49:56","guid":{"rendered":"https:\/\/wp.delphin.de\/?post_type=produkt&#038;p=1257"},"modified":"2025-11-18T14:58:08","modified_gmt":"2025-11-18T13:58:08","slug":"modular-data-acquisition-profimessage-d","status":"publish","type":"produkt","link":"https:\/\/www.delphin.de\/en\/produkte\/messgeraete-pruefgeraete\/modulare-messdatenerfassung-profimessage-d\/","title":{"rendered":"ProfiMessage D"},"content":{"rendered":"<div class=\"gb-container gb-container-1713c3d5 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\"><strong>Modular measured value acquisition ProfiMessage D<\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Modular platform for demanding measuring and testing tasks<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Whether on test benches for machines or in sophisticated systems - very different measured values often need to be recorded, monitored and analyzed simultaneously. This is precisely where the ProfiMessage D modular data acquisition system offers the right solution: the system can be flexibly adapted to your tasks and grows with your requirements. This means you can reliably cover a wide variety of applications with just one system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks to the self-sufficient data storage, your data is securely available at all times - regardless of the network. The integrated cloud connection makes current and historical measured values available to you anywhere, opening up new possibilities for evaluation and process optimization.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With its combination of flexibility, reliability and future-proofing, ProfiMessage D supports you in mastering your measurement tasks efficiently, cost-effectively and sustainably.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-5fe21863 gb-container-inner-shadow\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-210d8a23\">\n<div class=\"gb-grid-column gb-grid-column-94019e0a\"><div class=\"gb-container gb-container-94019e0a\"><div class=\"gb-inside-container\">\n\n<h3 class=\"wp-block-heading\">Product highlights<\/h3>\n\n\n\n<ul class=\"wp-block-list list has-medium-font-size\">\n<li>Precise data acquisition and secure storage with integrated signal pre-processing<\/li>\n\n\n\n<li>Reliable monitoring thanks to limit values and alarm functions<\/li>\n\n\n\n<li>Universal inputs for maximum measuring accuracy with a wide range of sensors<\/li>\n\n\n\n<li>High interference immunity due to galvanic isolation of the channels<\/li>\n\n\n\n<li>Flexible access via Ethernet in online mode or USB for fast readout<\/li>\n\n\n\n<li>Versatile interfaces such as ModBus, CAN bus, serial ports, PROFIBUS and PROFINET<\/li>\n\n\n\n<li>Compact, modular design for space-saving use and flexible expansion<\/li>\n<\/ul>\n\n<\/div><\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-b1fd9cee\"><div class=\"gb-container gb-container-b1fd9cee\"><div class=\"gb-inside-container\">\n\n<figure class=\"gb-block-image gb-block-image-3f0aecc9\"><img decoding=\"async\" width=\"1100\" height=\"1200\" class=\"gb-image gb-image-3f0aecc9\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-profimessage-d-250220.jpg\" alt=\"profimessage d product highlights\" title=\"delphin-website-product-philights-profimessage-e-250220\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-profimessage-d-250220.jpg 1100w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-profimessage-d-250220-275x300.jpg 275w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-profimessage-d-250220-939x1024.jpg 939w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-profimessage-d-250220-768x838.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-profimessage-d-250220-11x12.jpg 11w\" sizes=\"(max-width: 1100px) 100vw, 1100px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-7295ddc2\">\n\n<a class=\"gb-button gb-button-793cd39f gb-button-text gb-button-standard\" href=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/05\/PDF_ProfiMessage_D.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download PDF<\/a>\n\n\n\n<a class=\"gb-button gb-button-649c11e8 gb-button-text gb-button-standard\" href=\"https:\/\/www.youtube.com\/watch?v=h9xqwAdIZnk&amp;t=13s\" target=\"_blank\" rel=\"noopener noreferrer\">Watch video<\/a>\n\n\n\n<a class=\"gb-button gb-button-cdfc5b30 gb-button-text gb-button-standard\" href=\"https:\/\/www.delphin.de\/en\/modular-measurement-data-acquisition-system\/\" target=\"_blank\" rel=\"noopener noreferrer\">More in the blog<\/a>\n\n\n\n<div class=\"popup-button-block alignright gb-container\"\n    style=\"\">\n\n    <a class=\"gb-button gb-button-text gb-button-standard popup-button\" href=\"https:\/\/www.delphin.de\/wp-content\/uploads\/wr360\/produkte\/profimessage_d\/viewer.html\" data-featherlight=\"iframe\" data-featherlight-iframe-style=\"height:85vh;width:85vw;\">360\u00b0 view<\/a>\n\n<\/div>\n<\/div>\n<\/div><\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-670448aa gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">I\/Os and interfaces<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The clear display of all inputs and outputs as well as communication interfaces enables efficient system integration and uncomplicated commissioning.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"delphin-io grid-3x2 has-image\"><div class=\"delphin-io__col col-left\"><div class=\"delphin-io__box area-inputs\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Input signals<\/h3><div class=\"delphin-io__content\"><ul>\n<li>Voltage\/Currents<\/li>\n<li>Thermocouples<\/li>\n<li>Resistance\/RTD<\/li>\n<li>Digital input<\/li>\n<li>Frequencies<\/li>\n<\/ul>\n<\/div><\/div><div class=\"delphin-io__box area-outputs\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Output signals<\/h3><div class=\"delphin-io__content\"><ul>\n<li>Voltage\/Currents<\/li>\n<li>Digital output<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div><div class=\"delphin-io__center area-center\"><figure class=\"delphin-io__figure\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/PMD-mit-PN-mit-Display-1024x548.png\" alt=\"ProfiMessage D Hardware\" title=\"\"><\/figure><h2 class=\"delphin-io__main-title\">ProfiMessage D<\/h2><\/div><div class=\"delphin-io__col col-right\"><div class=\"delphin-io__box area-interfaces\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Interfaces<\/h3><div class=\"delphin-io__content\"><ul>\n<li>LAN<\/li>\n<li>USB<\/li>\n<li>RS 232\/485<\/li>\n<\/ul>\n<\/div><\/div><div class=\"delphin-io__box area-protocols\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Protocols<\/h3><div class=\"delphin-io__content\"><ul>\n<li>PROFINET<\/li>\n<li>PROFIBUS<\/li>\n<li>CAN<\/li>\n<li>Modbus TCP<\/li>\n<li>Modbus RTU<\/li>\n<li>OPC UA<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/section>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Here you will find an overview of the standard and optionally available <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/#interfaces-and-protocols\"><strong>Hardware interfaces and protocols.<\/strong><\/a> Find out more about the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/schnittstellen\/\"><strong>interface diversity<\/strong><\/a> our measurement technology software.<\/p>\n\n\n<div class=\"gb-container gb-container-4c28cd1a gb-container-00a24a60\">\n<div class=\"gb-container gb-container-a98c2238\"><\/div>\n\n<div class=\"gb-container gb-container-6d978ee7\">\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>Inputs and outputs are differential, highly accurate and galvanically isolated from each other and from the supply voltage.<\/strong> <strong>Typical solutions with the ProfiMessage D modular data acquisition system include<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Monitoring systems<\/li>\n\n\n\n<li>Process data acquisition and preprocessing<\/li>\n\n\n\n<li>Fault-data acquisition and fault diagnostics<\/li>\n\n\n\n<li>Acquisition, processing and recording of PLC and field bus signals<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Automation device for experiments and test stands<\/li>\n\n\n\n<li>Remote monitoring device for plant and machinery<\/li>\n\n\n\n<li>Laboratory measurement acquisition and automation<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div>\n<\/div>\n\n<div id=\"functions\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Functions<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-cc11b099 gb-container-00a24a60\">\n<div class=\"gb-container gb-container-f3e3829a gb-container-781ccc9b\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">All in one: capture, process and save with ProfiMessage D<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ProfiMessage D combines precise data acquisition, signal processing, limit value monitoring and secure storage in a single device. Modular I\/O modules and versatile interfaces allow it to be flexibly integrated and enable fast, practical implementation of demanding measuring and monitoring tasks.<\/p>\n\n\n\n<div class=\"wp-block-columns has-accent-color has-text-color has-link-color wp-elements-789f88d39d5b80648330e227f42321c8 is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>Quick access to all measured values<\/strong> - Data is transferred to the network at high speed via the LAN\/TCP interface. Users can access the device from any PC on the intranet or Internet and also use common services such as NTP, SFTP, HTTP or SMTP. The internal data memory can also be conveniently read out via LAN.<\/li>\n\n\n\n<li><strong>Flexible integration of devices and sensors<\/strong> - The RS232\/RS485 interfaces enable the connection of individual or proprietary protocols. This makes it easy to integrate climate chambers, laboratory equipment, power meters or GPS receivers.<\/li>\n\n\n\n<li><strong>High adaptability in the field<\/strong> - Any identifier can be read, written and processed via the freely programmable CAN bus. At the same time, the system supports Modbus TCP\/RTU in master or slave mode.<\/li>\n\n\n\n<li><strong>Ready for Industry 4.0<\/strong> - The integrated OPC UA client\/server interface allows measured values and limit value violations to be securely forwarded to subsystems, PLC controllers or PCT systems. This ensures future viability in IoT and cloud environments.<\/li>\n\n\n\n<li><strong>Convenient data backup<\/strong> - Stored measurement data can be transferred directly via USB stick or LAN. This means that network-independent operation is also possible at any time.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>Seamless connection to automation systems<\/strong> - Two independent PROFIBUS DP slave interfaces allow integration into existing control systems, including redundant operating mode in accordance with the PNO standard.<\/li>\n\n\n\n<li><strong>Scalable for growing requirements<\/strong> - Up to 20 slave devices can be connected to a master device via the expansion bus. Each I\/O module can be flexibly configured to cover different measured variables such as voltage, current or temperature.<\/li>\n\n\n\n<li><strong>Reliable and interference-free measurement<\/strong> - Differential, high-precision and galvanically isolated inputs and outputs prevent earth loops and also reliably detect sensors with potential.<\/li>\n\n\n\n<li><strong>Direct operation and quick control<\/strong> - An integrated display with jog wheel allows easy setting of network properties and direct reading of current measured values.<\/li>\n\n\n\n<li><strong>Simple and efficient configuration<\/strong> - With the software supplied, setup is clear and intuitive, similar to Windows Explorer. Configurations can be created offline, saved and quickly exchanged if required - for maximum flexibility in daily operation.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div><\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-8e21c017 gb-container-00a24a60\">\n<div class=\"gb-container gb-container-a92f0fef gb-container-00a24a60\">\n<div class=\"wp-block-image is-style-default\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"369\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-abnehmbare-klemmleisten-detail-breit-230419-1024x369.jpg\" alt=\"\" class=\"wp-image-4481\" style=\"width:1200px;height:undefinedpx\" title=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-abnehmbare-klemmleisten-detail-breit-230419-1024x369.jpg 1024w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-abnehmbare-klemmleisten-detail-breit-230419-300x108.jpg 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-abnehmbare-klemmleisten-detail-breit-230419-768x277.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-abnehmbare-klemmleisten-detail-breit-230419.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"gb-headline gb-headline-7a770ae8 gb-headline-text gb-headline-p-small\"><em>ProfiMessage D - Illustration of the exchangeable I\/O module cards (left) and the removable terminal blocks (right)<\/em><\/p>\n\n<\/div>\n<\/div>\n\n<div id=\"versions\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Versions<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-9e78ab53 gb-container-00a24a60\">\n\n<h2 class=\"gb-headline gb-headline-512ca132 gb-headline-text\">ProfiMessage D - modularly expandable and perfect for complex measurement tasks<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The ProfiMessage D impresses with its consistent modularity: each master or slave device can be equipped with up to two I\/O modules, with a total of nine different modules to choose from. Master devices without an internal I\/O module are also available for pure fieldbus applications. Up to 20 slave devices can be connected to a master device via a robust, real-time-capable extension bus using two-wire technology - distributed centrally or decentrally. This creates a highly flexible system that can be adapted precisely to the task at hand.<\/p>\n\n\n<div class=\"gb-container gb-container-f6e1e01f\">\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"369\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-modularitaet-und-skalierbarkeit-detail-breit-230419-1024x369.jpg\" alt=\"\" class=\"wp-image-4484\" style=\"width:1169px;height:421px\" title=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-modularitaet-und-skalierbarkeit-detail-breit-230419-1024x369.jpg 1024w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-modularitaet-und-skalierbarkeit-detail-breit-230419-300x108.jpg 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-modularitaet-und-skalierbarkeit-detail-breit-230419-768x277.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-profimessage-d-modularitaet-und-skalierbarkeit-detail-breit-230419.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"gb-headline gb-headline-82612f20 gb-headline-text gb-headline-p-small\"><em>ProfiMessage D - Master and slave devices<\/em><\/p>\n\n<\/div>\n\n\n<figure class=\"wp-block-table col-1-180px\"><table><thead><tr><th>I\/O-Modules<\/th><th class=\"translation-block\"><strong>Analog inputs<\/strong><\/th><th><strong>Analog outputs<\/strong><\/th><th><strong>Frequencies \/ Status inputs<\/strong><\/th><th>Status inputs<\/th><th>Switch outputs<\/th><th>Total sampling rate<\/th><\/tr><\/thead><tbody><tr><td>ADGT<\/td><td class=\"translation-block\">8 channels, V \/mV, <br>20 mA, RTD, thermocouples<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>60 Hz<\/td><\/tr><tr><td>ADIT<\/td><td class=\"translation-block\">10 channels, <br>V \/ mV, 20 mA, RTD, thermocouples<\/td><td>1 channel <br>20 mA<\/td><td><\/td><td><\/td><td>1 channel<\/td><td>600 Hz<\/td><\/tr><tr><td>ADVP<\/td><td class=\"translation-block\">15 channels, <br>V \/ mV, 20 mA, RTD (max. 8), thermocouples<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>600 Hz<\/td><\/tr><tr><td>ADVT<\/td><td class=\"translation-block\">15 channels, <br>V \/ mV, 20 mA, thermocouples<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>600 Hz<\/td><\/tr><tr><td>AAST<\/td><td class=\"translation-block\">4 channels, V \/mV, <br>20 mA, RTD, thermocouples<\/td><td>4 channels <br>20 mA<\/td><td><\/td><td>2 channels<\/td><td>2 channels<\/td><td>600 Hz<\/td><\/tr><tr><td>IOIT<\/td><td><\/td><td><\/td><td><\/td><td>24 channels<\/td><td>1 channel<\/td><td><\/td><\/tr><tr><td>OTPT<\/td><td><\/td><td><\/td><td><\/td><td>1 channel<\/td><td>24 channels<\/td><td><\/td><\/tr><tr><td>DIOT<\/td><td><\/td><td><\/td><td>11 channels<\/td><td>1 channel<\/td><td>16 channels<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Here you will find an overview of the standard and optionally available <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/#interfaces-and-protocols\"><strong>Hardware interfaces and protocols.<\/strong><\/a> Find out more about the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/schnittstellen\/\"><strong>interface diversity<\/strong><\/a> our measurement technology software.<\/p>\n\n\n<div id=\"faq\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>FAQ<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-ccded961 gb-accordion\">\n<div class=\"gb-container gb-container-2509029c gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3aa15fe0 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-3aa15fe0\"><span class=\"gb-button-text\"><strong>What is the ProfiMessage D and what is this modular data acquisition system used for?<\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-fb22c8ec\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-fb22c8ec\">\n\n<p class=\"wp-block-paragraph\">The ProfiMessage D is a modular measuring, monitoring and automation system for industrial applications. It is used wherever precise measured value acquisition, monitoring and control are required, e.g. in production, test laboratories, energy systems, mechanical engineering or for long-term measurements.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-dbac5b0c gb-accordion\">\n<div class=\"gb-container gb-container-7ec74a40 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-f13b1b9f gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-f13b1b9f\"><span class=\"gb-button-text\"><strong>What special functions and features does modular data acquisition offer?<\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-28d4502a\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-28d4502a\">\n\n<p class=\"wp-block-paragraph\"><strong>The most important features include:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Modularity: Flexible combination of different I\/O modules for individual measurement tasks<\/li>\n\n\n\n<li>High measuring accuracy: Up to 24-bit resolution and fast sampling rates of up to 600 Hz depending on the module<\/li>\n\n\n\n<li>Galvanic isolation: Minimizes susceptibility to interference and protects sensors and electronics<\/li>\n\n\n\n<li>Wide range of interfaces: PROFIBUS, PROFINET, Ethernet, Modbus, CAN, OPC UA, USB etc.<\/li>\n\n\n\n<li>Self-sufficient data recording: 32 GB internal memory for network-independent measurements<\/li>\n<\/ul>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-2742a053 gb-accordion\">\n<div class=\"gb-container gb-container-b15a3507 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-ead49131 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-ead49131\"><span class=\"gb-button-text\"><strong>Which sensors can be connected to the modular data acquisition system?<\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-c6cb7265\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-c6cb7265\">\n\n<p class=\"wp-block-paragraph\">The ProfiMessage D supports a wide range of sensor and signal types via the various I\/O modules: e.g. voltage, current, thermocouples, resistance thermometers (Pt100 \/ Pt1000), frequency\/status inputs, digital I\/Os. The galvanic isolation and the high resolution and measuring accuracy also make the system suitable for demanding measuring tasks. This covers both simple and high-precision measurement tasks.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-7d09f4ed gb-accordion\">\n<div class=\"gb-container gb-container-e77e4a41 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-6a8683c1 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-6a8683c1\"><span class=\"gb-button-text\"><strong><strong>How does the ProfiMessage D fit into an industrial data acquisition system or an IoT environment?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-548c6387\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-548c6387\">\n\n<p class=\"wp-block-paragraph\">Thanks to modern interfaces such as OPC UA (client\/server), Modbus TCP\/RTU, PROFINET or PROFIBUS, the system can be easily integrated into networked production environments and automation systems. The modular expandability also enables flexible adaptation to growing systems.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-06c25e50 gb-accordion\">\n<div class=\"gb-container gb-container-570b525d gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-525d7295 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-525d7295\"><span class=\"gb-button-text\"><strong><strong><strong>How is the modular data acquisition system expanded and scaled?<\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-2575f83c\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-2575f83c\">\n\n<ul class=\"wp-block-list\">\n<li>Master and slave devices can be equipped with up to two I\/O modules<\/li>\n\n\n\n<li>Up to 20 slaves can be connected to a master device via the extension bus<\/li>\n\n\n\n<li>Modules can be added or replaced at any time<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This allows the system to grow flexibly with increasing measuring points, new sensors or future requirements.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-34c9aa86 gb-accordion\">\n<div class=\"gb-container gb-container-4d68a8d5 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-1e614f8d gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-1e614f8d\"><span class=\"gb-button-text\"><strong><strong><strong><strong>What must be observed when commissioning the data acquisition system?<\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-f24568ec\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-f24568ec\">\n\n<p class=\"wp-block-paragraph\">Commissioning is supported by intuitive configuration software. Important are:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Selection of suitable modules<\/li>\n\n\n\n<li>Correct interface and network parameters<\/li>\n\n\n\n<li>Parameterization of automation and limit value functions (software channels)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If required, Delphin provides support with advice and commissioning service.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-4a29233b gb-accordion\">\n<div class=\"gb-container gb-container-f3392dc5 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-8edb68da gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-8edb68da\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong>For which industries is the ProfiMessage D modular data acquisition system particularly suitable?<\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-9b6d0dea\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-9b6d0dea\">\n\n<ul class=\"wp-block-list\">\n<li>Mechanical and plant engineering<\/li>\n\n\n\n<li>Energy technology<\/li>\n\n\n\n<li>Research &amp; Development<\/li>\n\n\n\n<li>Manufacturing and production companies<\/li>\n\n\n\n<li>Building technology \/ monitoring<\/li>\n\n\n\n<li>Environmental and testing technology<\/li>\n\n\n\n<li>Demanding industrial environments<\/li>\n<\/ul>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div id=\"technische-daten\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Technical specifications<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-908ba896 gb-container-00a24a60\">\n<div class=\"gb-container gb-container-f1836c22 del-accordion-preview gb-accordion\">\n<div class=\"gb-container gb-container-fe4b4821 gb-accordion__item\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3c1e3b88 gb-accordion__toggle\" id=\"gb-accordion-toggle-3c1e3b88\"><span class=\"gb-button-text\">All data overview<\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" ariahidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" ariahidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-8b8b1a0d\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-8b8b1a0d\">\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Module type<br>(2 modules per master \/ slave)<\/strong><\/td><td><strong>ADVT \/ AAST \/ ADIT<\/strong><\/td><td><strong>ADGT<\/strong><\/td><td><strong>IOIT \/ OTPT \/ DIOT<\/strong><\/td><\/tr><tr><td class=\"translation-block\"><strong>Analog inputs<\/strong><\/td><td><strong>15 \/ 4 \/ 10<\/strong><\/td><td><strong>8<\/strong><\/td><td><strong>-<\/strong><\/td><\/tr><tr><td>Sensors<\/td><td class=\"translation-block\">mv, mA, Thermocouples, RTD (RTD except ADVT)<\/td><td>mv, mA, Thermocouples, RTD<\/td><td>-<\/td><\/tr><tr><td>Total sampling rate<\/td><td>600 Hz<\/td><td>60 Hz<\/td><td>-<\/td><\/tr><tr><td>Voltage and current measurement range<\/td><td colspan=\"2\">156 mV .. 10 V, \u00b1 156 mV .. \u00b1 10 V \/ 0 .. 20 mA, 4 .. mA,<br>\u00b1 20 mA<\/td><td>-<\/td><\/tr><tr><td>Galvanic isolation to system<\/td><td>750 VDC&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/td><td>400 VDC<\/td><td>-<\/td><\/tr><tr><td>Galvanic isolation channel to channel<\/td><td>110 V&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/td><td>650 V<\/td><td>-<\/td><\/tr><tr><td>Resolution\/Type ADC<\/td><td>24 bit Sigma-Delta<\/td><td>24 bit Sigma-Delta<\/td><td>-<\/td><\/tr><tr><td>Measurement accuracy<\/td><td colspan=\"2\">Voltage, current: 0.01 % of the measuring range end value<br>Thermocouples: 0.1 % of measuring range after sensor compensation*<\/td><td>-<\/td><\/tr><tr><td><strong>Measuring accuracy Pt 100 <\/strong>(4-wire connection)<\/td><td colspan=\"2\">Measuring range -260 \u00b0C to 147 \u00b0C: 0.10 \u00b0C<br>Measuring range -260 \u00b0C to 596 \u00b0C: 0.20 \u00b0C<br>Measuring range -260 \u00b0C to 849 \u00b0C: 0.43 \u00b0C<\/td><td>-<\/td><\/tr><tr><td><strong>Measuring accuracy Pt 1000 <\/strong>(4-wire connection)<\/td><td colspan=\"2\">Measuring range -260 \u00b0C to 64 \u00b0C: 0.10 \u00b0C<br>Measuring range -260 \u00b0C to 408 \u00b0C: 0.15 \u00b0C<br>Measuring range -260 \u00b0C to 849 \u00b0C: 0.35\u00b0C<\/td><td>-<\/td><\/tr><tr><td><strong>Analog outputs<\/strong><\/td><td><strong>- \/ 4 \/ 1<\/strong><\/td><td><strong>-<\/strong><\/td><td><strong>-<\/strong><\/td><\/tr><tr><td>Resolution<\/td><td>16 bit<\/td><td>-<\/td><td>-<\/td><\/tr><tr><td>Potential isolation<\/td><td>750 V<\/td><td>-<\/td><td>-<\/td><\/tr><tr><td>Output<\/td><td>0\/4 .. 20 mA<\/td><td>-<\/td><td>-<\/td><\/tr><tr><td>Min. load \/ max. burden<\/td><td>650 \u03a9<\/td><td>-<\/td><td>-<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-small-font-size\"><em>* These measuring accuracies apply to positive measuring temperatures (&gt; 0\u00b0C). For measurements in the negative temperature range, we recommend calibration at the respective operating point.<\/em><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Module type<br>(2 modules per master \/ slave)<\/strong><\/td><td><strong>ADVT \/ AAST \/ ADIT<\/strong><\/td><td><strong>ADGT<\/strong><\/td><td><strong>IOIT \/ OTPT \/ DIOT<\/strong><\/td><\/tr><tr><td><strong>Digital<br>inputs<\/strong><\/td><td><strong>- \/ 2 \/ -<\/strong><\/td><td><strong>-<\/strong><\/td><td><strong>24 \/ 1 \/ 12<\/strong><\/td><\/tr><tr><td>Thereof with frequency measurement \/ counting function<\/td><td>- \/ - \/ -<\/td><td>-<\/td><td>- \/ - \/ 11<\/td><\/tr><tr><td>Max. measurement frequency<\/td><td>- \/ - \/ -<\/td><td>-<\/td><td>- \/ - \/ 30 kHz<\/td><\/tr><tr><td>Input measurement range<\/td><td colspan=\"3\">low: 0 .. 1.5 VDC@0 ... 1.5 mA \/ high: 4.8 ... 90 VDC@ 2.5 ... 3.5 mADC<\/td><\/tr><tr><td>Potential isolation<\/td><td colspan=\"3\">2.5 kV<\/td><\/tr><tr><td><strong>Digital outputs<\/strong><\/td><td><strong>- \/ 2 \/ 1<\/strong><\/td><td><strong>-<\/strong><\/td><td><strong>1 \/ 24 \/ 16<\/strong><\/td><\/tr><tr><td>Potential isolation<\/td><td colspan=\"3\">2.5 kV<\/td><\/tr><tr><td>Switching voltage<\/td><td colspan=\"3\">max. 50 VDC@2.5 A<\/td><\/tr><tr><td><strong>Data storage<\/strong><\/td><\/tr><tr><td>Internal<\/td><td colspan=\"3\">32 GB (approx. 960 million measured values)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Module type<br>(2 modules per master \/ slave)<\/strong><\/td><td><strong>ADVT \/ AAST \/ ADIT<\/strong><\/td><td><strong>ADGT<\/strong><\/td><td><strong>IOIT \/ OTPT \/ DIOT<\/strong><\/td><\/tr><tr><td><strong>Interfaces<\/strong><\/td><\/tr><tr><td>Physical equipment<br>COM 1 \/ COM 2<\/td><td colspan=\"3\">RS485, 9-pole sub-D socket, IEC 61158-2<\/td><\/tr><tr><td>Physical equipment<br>COM 3 \/ COM 4<\/td><td colspan=\"3\">RS232, 9-pole sub-D-socket (COM 3), 9-pole sub-D plug (COM 4)<\/td><\/tr><tr><td>Protocols COM 1 \/ COM 2<\/td><td colspan=\"3\">PROFIBUS DPV1 slave (both interfaces), also redundant according to PNO 2.212 V1.2<\/td><\/tr><tr><td>Protocols COM 1 .. COM 4<\/td><td colspan=\"3\">Modbus RTU master \/ slave, customer-specific protocols, ASCII<\/td><\/tr><tr><td>TCP\/IP<\/td><td colspan=\"3\">RJ45 (8-pin STP socket), 1000Base-T; protocols: TCP\/IP, HTTP, SMTP, NTP, Modbus TCP Client (optional) \/ Server, OPC UA Client \/ Server, OPC UA HA Server (optional)<\/td><\/tr><tr><td>PROFINET (TCP\/IP)<\/td><td colspan=\"3\">PROFINET RT Device, IO\/MRP\/LLDP, Conf Class B, RT Class 1,<br>Netload Class III, I&amp;M 0,1,2,3,5, 2xRJ45 100MBit\/s full duplex<\/td><\/tr><tr><td>USB<\/td><td colspan=\"3\">USB 2.0 type C for reading out stored data<\/td><\/tr><tr><td>CAN<\/td><td colspan=\"3\">9-pole sub-D socket, Protocols: CAN, RAW; baud rates: 25 k .. 1 MBaud; dbc-import possible<\/td><\/tr><tr><td>Module bus baud rate \/ length<\/td><td colspan=\"3\">1 MBaud \/ 10 m ... 25 kBaud \/ 100m<\/td><\/tr><tr><td><strong>General technical information<\/strong><\/td><\/tr><tr><td>Dimensions \/ weight<\/td><td colspan=\"3\">W 200 x H 73 x D 137 mm \/ 1 kg<\/td><\/tr><tr><td>Fixing<\/td><td colspan=\"3\">Mounting rail DIN EN 60715 or screw mounting<\/td><\/tr><tr><td>Connecting terminals<\/td><td colspan=\"3\">Detachable screw terminals, 33 terminals in 2 rows, lead protection, <br>connecting cabling max. 2.5 mm\u00b2<\/td><\/tr><tr><td>Display<\/td><td colspan=\"3\">7 lines, operation via jog wheel<\/td><\/tr><tr><td>Temperature range<\/td><td colspan=\"3\">-20 .. 50 \u00b0C<\/td><\/tr><tr><td>Humidity<\/td><td colspan=\"3\">max. 90 % relative humidity, non-condensing<\/td><\/tr><tr><td>Supply voltage<\/td><td colspan=\"3\">12 .. 24 VDC \/ \u00b1 10 %<\/td><\/tr><tr><td>Power input<\/td><td colspan=\"3\">&lt; 10 watts<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><em>Status: 13.11.2025<\/em><\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div id=\"software\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Software<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-41fd161a gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">Software interfaces<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern software interfaces make ProfiMessage D compatible with common industrial and IoT systems.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"delphin-softio grid-3x1\"><div class=\"softio-box softio-interfaces\" style=\"--box-bg:#FFFFFF;\"><h3 class=\"softio-title\">Interfaces<\/h3><div class=\"softio-content\"><ul>\n<li>OPC UA (Server\/Client)<\/li>\n<li>OPC UA (Server\/Client)<\/li>\n<li>OPC UA HA (Server)<\/li>\n<li>API<\/li>\n<li>Python<\/li>\n<li>SQL<\/li>\n<li>LabView<\/li>\n<li>Diadem<\/li>\n<li>Modbus TCP<\/li>\n<li>DasyLab<\/li>\n<\/ul>\n<\/div><\/div><div class=\"softio-box softio-dataservice\" style=\"--box-bg:#FFFFFF;\"><h3 class=\"softio-title\">DataService \/ Data Center<\/h3><\/div><div class=\"softio-hero\" style=\"--box-bg:#FFFFFF;\"><h2 class=\"softio-main-title\">ProfiMessage D<\/h2><figure class=\"softio-figure\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/PMD-mit-PN-mit-Display-1024x548.png\" alt=\"ProfiMessage D Hardware\" title=\"\"><\/figure><\/div><\/section>\n<\/div><\/div>\n\n<div class=\"gb-container gb-container-601b0465\">\n\n<h2 class=\"wp-block-heading has-text-align-left\">Suitable software for ProfiMessage D<\/h2>\n\n\n<div class=\"produkt-tabs-block\" style=\"\">\n    <div class=\"produkt-tabs__container\"><div class=\"produkt-tabs\"><div class='produkt-tab activeTab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Go<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Basic<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Klicks<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal 20 Basic<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal 20 Go<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-300x225.png\" class=\"produkt-tab__img\" alt=\"Central measurement data management Delphin Date Canter\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-300x225.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-768x576.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-16x12.png 16w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025.png 987w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>Delphin Data Center<\/div><\/div><\/div><\/div><div class=\"produkt-details\"><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Go<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Data acquisition and analysis<\/h3><p class='produkt-detail__text'>Display and monitor measurement data live | Intuitive operation and easy handling without programming knowledge | Versatile diagram and analysis functions for various measurement data | Ready for data acquisition and analysis in just a few minutes<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-go\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-go-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Basic<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Operating and monitoring<\/h3><p class='produkt-detail__text'>Reliably record and save measurement data | Clearly display and evaluate measured values | Quickly set up and operate projects without programming effort | Ideal for individual measuring stations up to small measuring systems<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-basic\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-basic-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Klicks<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Automate and control<\/h3><p class='produkt-detail__text'>Monitor measurement data and control processes directly | Create automations simply by dragging and dropping | Suitable for complex test benches and automation tasks | Implement and adapt projects without programming knowledge<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-klicks\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-klicks-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal 20 Basic<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Visualisation and operation<\/h3><p class='produkt-detail__text'>Easily create your own visualizations for measurement data | Conveniently evaluate and log measurement and process data | Intuitive interface for efficient work without programming knowledge | Ideal for individual measuring stations through to complex monitoring solutions<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal-20\/profisignal-20-basic\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal20-basic-230329-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal 20 Go<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Data acquisition and saving<\/h3><p class='produkt-detail__text'>Display and monitor signals and processes in real time | Easy handling with no training required | Access to measurement data from PC, tablet or smartphone | Ready for many measurement and analysis tasks in just a few minutes<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal-20\/profisignal-20-go\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal20-go-230329-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>Delphin Data Center<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Central measurement data management<\/h3><p class='produkt-detail__text'>Central storage of operating, maintenance and process data | Cross-site real-time monitoring of machine and process statuses | Modular structure makes it easy to adapt to growing plant and process environments<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/delphin-data-center\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-ddc-230329-1-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><\/div><\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-c0f069fe gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">Software channels as extended functions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Realise and execute monitoring and automation tasks easily<\/strong>&nbsp;<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Our measuring and testing devices have extended functions, which are summarized under the term software channels. The online measurement data is offset against the software channels and then used for visualization, storage or control.\u00a0\u00a0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this way, entire programme sequences can be configured very simply and intuitively with the regulation and control function. These then run autonomously without PC support. This is how you use your data logger effectively, also as a monitoring device or PLC replacement.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The software channels enable functions such as limit value monitoring, integration or online calculation and are configured very easily. This means that even users who are not experts in programming can easily implement their own monitoring tasks or balancing independently in the unit.&nbsp;<\/p>\n\n\n\n<a class=\"gb-button gb-button-e5af81a4 gb-button-text gb-button-small\" href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/software-channels\/\" target=\"_blank\" rel=\"noopener noreferrer\">More information<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Modular measuring, monitoring and automation in one device.<\/p>","protected":false},"author":3,"featured_media":15652,"parent":1168,"menu_order":2,"template":"","format":"standard","categories":[1],"tags":[],"class_list":["post-1257","produkt","type-produkt","status-publish","format-standard","has-post-thumbnail","hentry","category-hardware"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/types\/produkt"}],"author":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/users\/3"}],"version-history":[{"count":42,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1257\/revisions"}],"predecessor-version":[{"id":17187,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1257\/revisions\/17187"}],"up":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media\/15652"}],"wp:attachment":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media?parent=1257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/categories?post=1257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/tags?post=1257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}