{"id":939,"date":"2023-03-04T17:57:47","date_gmt":"2023-03-04T16:57:47","guid":{"rendered":"https:\/\/wp.delphin.de\/?post_type=produkt&#038;p=939"},"modified":"2026-08-05T15:18:08","modified_gmt":"2026-08-05T13:18:08","slug":"autonomous-data-logger-expert-logger","status":"publish","type":"produkt","link":"https:\/\/www.delphin.de\/en\/produkte\/messgeraete-pruefgeraete\/autarker-datenlogger-expert-logger\/","title":{"rendered":"Expert Logger"},"content":{"rendered":"<div class=\"gb-container gb-container-4dc97677 gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\"><strong>Measurement data acquisition with Expert Logger<\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Analog and digital signals under control<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Whether in research, industry or plant monitoring - as a universal measurement data logger, the Expert Logger offers a powerful and flexible platform for the precise acquisition, recording and analysis of technical measurement data. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The modular architecture enables use in a wide range of applications - from mobile data acquisition to permanent system integration. Thanks to versatile interfaces, simple configuration and integrated intelligence, the Expert Logger can be quickly and efficiently integrated into existing processes. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This turns complex measurement technology into a practical solution - tailored precisely to your requirements.<\/p>\n\n<\/div>\n\n<div class=\"gb-container gb-container-5fe21863 gb-container-inner-shadow\">\n<div class=\"gb-grid-wrapper gb-grid-wrapper-210d8a23\">\n<div class=\"gb-grid-column gb-grid-column-94019e0a\"><div class=\"gb-container gb-container-94019e0a\"><div class=\"gb-inside-container\">\n\n<h3 class=\"wp-block-heading\">Product highlights<\/h3>\n\n\n\n<ul class=\"wp-block-list list has-medium-font-size\">\n<li>Processes up to 46 analog input channels<\/li>\n\n\n\n<li>FPGA technology ensures fast and precise measurements<\/li>\n\n\n\n<li>Connection via USB, LAN, LTE and various fieldbuses<\/li>\n\n\n\n<li>Stores up to 960 million measured values internally<\/li>\n\n\n\n<li>PUSH function sends measurement data automatically <\/li>\n\n\n\n<li>Four versions for different duct requirements<\/li>\n\n\n\n<li>Software channels enable internal signal processing<\/li>\n<\/ul>\n\n<\/div><\/div><\/div>\n\n<div class=\"gb-grid-column gb-grid-column-68ef6801\"><div class=\"gb-container gb-container-68ef6801\"><div class=\"gb-inside-container\">\n\n<figure class=\"gb-block-image gb-block-image-3f0aecc9\"><img decoding=\"async\" width=\"1100\" height=\"1200\" class=\"gb-image gb-image-3f0aecc9\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-logger-250220.jpg\" alt=\"Data logger Product highlight\" title=\"delphin-website-product-hilights-expert-logger-250220\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-logger-250220.jpg 1100w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-logger-250220-275x300.jpg 275w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-logger-250220-939x1024.jpg 939w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-logger-250220-768x838.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-webseite-produkthilights-expert-logger-250220-11x12.jpg 11w\" sizes=\"(max-width: 1100px) 100vw, 1100px\" \/><\/figure>\n\n\n<div class=\"gb-container gb-container-7295ddc2\">\n\n<a class=\"gb-button gb-button-793cd39f gb-button-text gb-button-standard\" href=\"https:\/\/www.youtube.com\/watch?v=_tfU4bBzIlc\" target=\"_blank\" rel=\"noopener noreferrer\">Watch video<\/a>\n\n\n\n<a class=\"gb-button gb-button-cdfc5b30 gb-button-text gb-button-standard\" href=\"https:\/\/www.delphin.de\/en\/expert-logger-data-logger\/\" target=\"_blank\" rel=\"noopener noreferrer\">More in the blog<\/a>\n\n\n\n<div class=\"popup-button-block alignright gb-container\"\n    style=\"\">\n\n    <a class=\"gb-button gb-button-text gb-button-standard popup-button\" href=\"https:\/\/www.delphin.de\/wp-content\/uploads\/wr360\/produkte\/expert_logger\/viewer.html\" data-featherlight=\"iframe\" data-featherlight-iframe-style=\"height:85vh;width:85vw;\">360\u00b0 view<\/a>\n\n<\/div>\n<\/div>\n<\/div><\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-670448aa gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">I\/Os and interfaces<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The clear display of all inputs and outputs as well as communication interfaces enables efficient system integration and uncomplicated commissioning.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"delphin-io grid-3x2 has-image\"><div class=\"delphin-io__col col-left\"><div class=\"delphin-io__box area-inputs\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Input signals<\/h3><div class=\"delphin-io__content\"><ul>\n<li>Voltage\/Currents<\/li>\n<li>Thermocouples<\/li>\n<li>DMS<\/li>\n<li>Resistance\/RTD<\/li>\n<li>Digital input<\/li>\n<li>Frequencies\/SDI-12<\/li>\n<\/ul>\n<\/div><\/div><div class=\"delphin-io__box area-outputs\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Output signals<\/h3><div class=\"delphin-io__content\"><ul>\n<li>Voltage\/Currents<\/li>\n<li>PWM<\/li>\n<li>Digital output<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div><div class=\"delphin-io__center area-center\"><figure class=\"delphin-io__figure\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/20250108_Expert_Logger_2-1024x484.png\" alt=\"Expert Logger Hardware\" title=\"\"><\/figure><h2 class=\"delphin-io__main-title\">Expert Logger<\/h2><\/div><div class=\"delphin-io__col col-right\"><div class=\"delphin-io__box area-interfaces\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Interfaces<\/h3><div class=\"delphin-io__content\"><ul>\n<li>LAN<\/li>\n<li>USB<\/li>\n<li>GPS<\/li>\n<li>RS 232\/485<\/li>\n<\/ul>\n<\/div><\/div><div class=\"delphin-io__box area-protocols\" style=\"--box-bg:#F8F8F8;\"><h3 class=\"delphin-io__title\">Protocols<\/h3><div class=\"delphin-io__content\"><ul>\n<li>PROFINET<\/li>\n<li>PROFIBUS<\/li>\n<li>CAN<\/li>\n<li>Modbus TCP<\/li>\n<li>Modbus RTU<\/li>\n<li>OPC UA<\/li>\n<li>OPC UA HA<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/section>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Here you will find an overview of the standard and optionally available <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/#interfaces-and-protocols\"><strong>Hardware interfaces and protocols.<\/strong><\/a> Find out more about the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/schnittstellen\/\"><strong>interface diversity<\/strong><\/a> our measurement technology software.<\/p>\n\n<\/div><\/div>\n\n<div class=\"gb-container gb-container-4c28cd1a gb-container-00a24a60\">\n<div class=\"gb-container gb-container-a98c2238\"><\/div>\n\n<div class=\"gb-container gb-container-6d978ee7\">\n\n<h2 class=\"wp-block-heading has-medium-font-size\">With Expert Logger, configuration does not become the main task, but users can concentrate fully on the measurement task. Typical solutions with the Expert Logger are<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Data logging<\/li>\n\n\n\n<li>Environmental measurement technology<\/li>\n\n\n\n<li>Product testing<\/li>\n\n\n\n<li>Measurement data diagnosis<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.delphin.de\/en\/solutions\/universal-data-acquisition\/laboratory-data-acquisition\/\" data-type=\"loesung\" data-id=\"854\">Laboratory data acquisition<\/a><\/li>\n\n\n\n<li>Trials and tests<\/li>\n\n\n\n<li>Energy optimization<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div>\n<\/div>\n\n<div id=\"functions\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Functions<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-f3e3829a gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">Expert Logger - Future-proof data logging for industry, the environment and test engineering<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Expert Logger is a powerful, modular system for recording, processing and forwarding measurement data. Whether stationary or mobile, in the laboratory or in the field - the Expert Logger impresses with its versatile interfaces, intelligent signal processing and simple operation. Industry 4.0 capability included.<\/p>\n\n\n\n<div class=\"wp-block-columns has-accent-color has-text-color has-link-color wp-elements-8e86f92830990ea37828204465da9e64 is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>Open communication with OPC UA<\/strong> - The Expert Logger supports OPC UA both as a server and as a client. This allows data to be exchanged securely and in a standardized manner with OPC UA-capable sensors, controllers or subsystems. This openness makes the system ideal for future-oriented applications in the sense of Industry 4.0.<\/li>\n\n\n\n<li><strong>Versatile interfaces for maximum integration<\/strong> - In addition to OPC UA, other industrial protocols such as PROFIBUS, Modbus, CAN bus and serial interfaces are also available. This allows the logger to be easily integrated into existing system architectures and automation solutions - without any additional hardware.<\/li>\n\n\n\n<li><strong>Fast sensor connection - well thought-out and clear<\/strong> - Sensors are connected via plug-in screw terminals, which simplifies installation and maintains clarity even with a high channel density. Four terminals each can be flexibly configured for differential inputs or Pt100(0) sensors in a four-wire circuit.<\/li>\n\n\n\n<li><strong>Simple configuration - online and offline<\/strong> - The device is configured intuitively using PC software. Changes can be prepared offline and transferred later. All settings are retained even if power is lost - for smooth commissioning and trouble-free use.<\/li>\n\n\n\n<li><strong>Intelligent signal processing directly in the device<\/strong> - Thanks to powerful software channels, measured values can be processed, calculated or evaluated internally - e.g. for averaging, limit value recognition, time functions or integrations. This reduces the need for external evaluation systems and saves time.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><strong>High storage capacity - internally and externally expandable<\/strong> - An internal memory of 32 GB enables the recording of up to 960 million measured values with millisecond-accurate time stamps. If required, the memory can be expanded as required via USB or NAS - even with event-controlled recording.<\/li>\n\n\n\n<li><strong>Secure data transfer - automated and flexible<\/strong> - Measured values can be automatically transferred to the Internet or to external storage devices using the PUSH function. The device also supports event-triggered transmissions with pre- and post-processing - ideal for time-critical applications or remote analysis.<\/li>\n\n\n\n<li><strong>Reliable monitoring and alarming<\/strong> - Thanks to built-in limit value monitoring, digital outputs can be controlled or automatic notifications can be triggered by e-mail and SMS. This allows you to keep an eye on critical values at all times - even remotely.<\/li>\n\n\n\n<li><strong>Mobile and self-sufficient operation<\/strong> - The logger can also be operated with batteries or rechargeable batteries for mains-independent use. Wake-up and measurement intervals are freely adjustable, which enables energy-efficient long-term operation - e.g. for environmental or outdoor measurements.<\/li>\n\n\n\n<li><strong>Direct access via touch display<\/strong> - The integrated touch display enables the configuration of basic settings such as IP address and netmask as well as the direct display of selected measured values. It can be operated by touch or alternatively via a connected USB mouse.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div><\/div>\n\n<div class=\"wp-block-image is-style-default\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"369\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-loesbare-schraubklemmen-detail-breit-230419-1024x369.jpg\" alt=\"\" class=\"wp-image-4473\" style=\"width:1920px;height:undefinedpx\" title=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-loesbare-schraubklemmen-detail-breit-230419-1024x369.jpg 1024w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-loesbare-schraubklemmen-detail-breit-230419-300x108.jpg 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-loesbare-schraubklemmen-detail-breit-230419-768x277.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-loesbare-schraubklemmen-detail-breit-230419.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"gb-headline gb-headline-02dd06ee gb-headline-text gb-headline-p-small\"><em>Expert Logger - detachable screw terminal illustration <\/em><\/p>\n\n\n<div id=\"versions\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Versions<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-4fdd3f91 gb-container-781ccc9b\"><div class=\"gb-inside-container\">\n<div class=\"gb-container gb-container-a92f0fef gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">Flexibly scalable - with large storage capacity and precise timestamp<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Expert Logger is available in four versions with varying numbers of analog and digital inputs. All models have an internal 32 GB memory for autonomous recording of up to 960 million measured values - including date and time stamp in the millisecond range. If required, the storage capacity can be flexibly expanded via USB or a NAS system.<\/p>\n\n\n<div class=\"wp-block-image is-style-default\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"369\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-typen-detail-breit-230419-1024x369.jpg\" alt=\"\" class=\"wp-image-4474\" style=\"width:1200px;height:undefinedpx\" title=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-typen-detail-breit-230419-1024x369.jpg 1024w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-typen-detail-breit-230419-300x108.jpg 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-typen-detail-breit-230419-768x277.jpg 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-expert-logger-typen-detail-breit-230419.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"gb-headline gb-headline-692741ee gb-headline-text gb-headline-p-small\"><em>Expert Logger - Available as type 100, type 200, type 300 or type 400 <\/em><\/p>\n\n<\/div>\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Type<\/th><th>100<\/th><th>200<\/th><th>300<\/th><th>400<\/th><\/tr><\/thead><tbody><tr><td>Analog inputs for mV, mA, thermocouples<\/td><td>16<\/td><td>32<\/td><td>46<\/td><td>16<\/td><\/tr><tr><td>Appropriate for RTD's<\/td><td>8<\/td><td>16<\/td><td>23<\/td><td>8<\/td><\/tr><tr><td>Sampling rates (measurements \/ sec.)<\/td><td>1000<\/td><td>2000<\/td><td>3000<\/td><td>1000<\/td><\/tr><tr><td>Analog outputs<\/td><td>0<\/td><td>0<\/td><td>0<\/td><td>6<\/td><\/tr><tr><td>Digital \/ Frequencies inputs<\/td><td>4<\/td><td>4<\/td><td>0<\/td><td>1<\/td><\/tr><tr><td>SDI 12 sensor bus<\/td><td>1<\/td><td>1<\/td><td>0<\/td><td>0<\/td><\/tr><tr><td>Digital \/ PWM outputs<\/td><td>4<\/td><td>4<\/td><td>0<\/td><td>0<\/td><\/tr><tr><td>Digital inputs \/ outputs<\/td><td>4<\/td><td>4<\/td><td>1<\/td><td>24<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Here you will find an overview of the standard and optionally available <a href=\"https:\/\/www.delphin.de\/en\/products\/measuring-testing-devices\/#interfaces-and-protocols\"><strong>Hardware interfaces and protocols.<\/strong><\/a> Find out more about the <a href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/schnittstellen\/\"><strong>interface diversity<\/strong><\/a> our measurement technology software.<\/p>\n\n\n<div id=\"faq\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>FAQ<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-ccded961 gb-accordion\">\n<div class=\"gb-container gb-container-2509029c gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3aa15fe0 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-3aa15fe0\"><span class=\"gb-button-text\"><strong><strong><strong><strong>What is the Expert Logger, and what is this data-logging device used for?<\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-fb22c8ec\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-fb22c8ec\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin Technology is a modular, universal data logger designed for the precise acquisition, storage, processing, and transmission of measurement data. It is suitable for use in industry, research, environmental measurement, test benches, energy optimization, and plant monitoring\u2014both in stationary and mobile applications.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-2de32bf9 gb-accordion\">\n<div class=\"gb-container gb-container-3b2c8e8e gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-35c1e4a9 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-35c1e4a9\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong>Which data logger is suitable for continuous 24\/7 industrial operation?<\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-30df3070\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-30df3070\">\n\n<p class=\"wp-block-paragraph\">Continuous operation requires devices with industrial-grade components and non-volatile configuration. The Expert Logger from Delphin is designed for 24\/7 industrial operation and enables continuous process monitoring for years\u2014without the need for a PC running continuously.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-06c25e50 gb-accordion\">\n<div class=\"gb-container gb-container-570b525d gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-525d7295 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-525d7295\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong>Are the settings on a data logger retained during a power outage?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-2575f83c\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-2575f83c\">\n\n<p class=\"wp-block-paragraph\">Yes\u2014with the Expert Logger from Delphin, all device settings are stored non-volatily and are fully preserved even in the event of a power loss. Once power is restored, the device automatically resumes measurement without requiring any reconfiguration.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-34c9aa86 gb-accordion\">\n<div class=\"gb-container gb-container-4d68a8d5 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-1e614f8d gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-1e614f8d\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong>How time-consuming is it to set up a modular data logger?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-f24568ec\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-f24568ec\">\n\n<p class=\"wp-block-paragraph\">Thanks to preconfigured interfaces, pluggable sensor connectors, and intuitive configuration software, commissioning the Expert Logger from Delphin is significantly faster than with many other modular systems. The configuration can be prepared offline and transferred to the device later.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-4a29233b gb-accordion\">\n<div class=\"gb-container gb-container-f3392dc5 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-8edb68da gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-8edb68da\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong>Can you operate a data logger without a connected PC?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-9b6d0dea\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-9b6d0dea\">\n\n<p class=\"wp-block-paragraph\">Yes\u2014the Expert Logger from Delphin features a built-in touchscreen display. This allows you to configure basic settings such as the IP address and subnet mask, as well as view selected measurement values directly on the device. It can be operated via the touchscreen or, alternatively, using a connected USB mouse.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-f698dad6 gb-accordion\">\n<div class=\"gb-container gb-container-e172799b gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-ceabee90 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-ceabee90\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong>Do you need programming skills to analyze data from the data logger?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-7e3bd8a6\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-7e3bd8a6\">\n\n<p class=\"wp-block-paragraph\">No\u2014the Expert Logger from Delphin processes measured values directly within the device via so-called software channels. Averaging, threshold detection, time functions, and integration are configured via settings rather than through programming. This allows the device to be used either as a standalone monitoring device or as a PLC replacement.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-bd0e1c0b gb-accordion\">\n<div class=\"gb-container gb-container-95878ccb gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-83f58ede gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-83f58ede\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong>What types of data can a universal data logger record?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-f5ef2a9e\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-f5ef2a9e\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin measures voltage and current, thermocouples, Pt100 and Pt1000 sensors (RTDs), resistances, strain gauges (SG), digital signals, and frequencies, as well as sensors on the SDI-12 sensor bus. All measurement parameters can be recorded simultaneously in a single device.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-ed4e27c2 gb-accordion\">\n<div class=\"gb-container gb-container-148c1fbc gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-f7d90849 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-f7d90849\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong>How many measurement channels can a data logger record simultaneously?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-f5e05273\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-f5e05273\">\n\n<p class=\"wp-block-paragraph\">Depending on the device type, the Expert Logger offers between Delphin and 46 analog channels, as well as additional digital inputs and outputs. The four models offer 16, 32, 46, and 16 analog inputs, respectively\u2014half of which can be used for Pt100(0) sensors in a four-wire configuration.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-3f9a3cd7 gb-accordion\">\n<div class=\"gb-container gb-container-5e6419dc gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-43e2e5fb gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-43e2e5fb\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong>How exactly does an industrial data logger measure temperature, voltage, and current?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-723ba755\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-723ba755\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin uses a 24-bit sigma-delta converter and achieves an accuracy of 0.01 % of the full-scale value for voltage and current measurements, and 0.02 % for resistance measurements in a 4-wire configuration. Pt100 measurements are accurate to 0.10 \u00b0C. The voltage measurement ranges extend from \u00b1156 mV to \u00b110 V.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-9ac758ae gb-accordion\">\n<div class=\"gb-container gb-container-210e2485 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3667ee25 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-3667ee25\"><span class=\"gb-button-text\"><strong>How quickly does a data logger sample measurements?<\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-8dd0cf38\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-8dd0cf38\">\n\n<p class=\"wp-block-paragraph\">Thanks to FPGA-based measurement data acquisition, the Expert Logger from Delphin achieves a total sampling rate of 1,000 Hz per channel group\u2014meaning up to 3,000 measurements per second for the Type 300, which has three groups. This allows even faster process operations to be documented seamlessly.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-faaf3495 gb-accordion\">\n<div class=\"gb-container gb-container-8445847d gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-23b1e257 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-23b1e257\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong>How are thermocouples in data loggers cold-junction compensated?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-bfc5a11e\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-bfc5a11e\">\n\n<p class=\"wp-block-paragraph\">Depending on the model, the Expert Logger from Delphin has two to six internal reference measurement points. This achieves an accuracy of 0.1 % of the measurement range after sensor compensation. Alternatively, an external thermoblock with an accuracy of 0.3 K can be connected.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-5cbb4739 gb-accordion\">\n<div class=\"gb-container gb-container-123768e9 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-73b47094 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-73b47094\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong>Which data logger is suitable for strain gauges (SG)?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-133a339e\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-133a339e\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin, in its 100 and 200 models, offers an integrated strain gauge supply voltage\u20145 VDC \u00b110 mV internally, and externally selectable at 1, 2.5, 5, or 10 V. This allows for force, pressure, and strain measurements without the need for additional amplifier hardware.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-cc6d28fe gb-accordion\">\n<div class=\"gb-container gb-container-28d68ddf gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-a5e96ee4 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-a5e96ee4\"><span class=\"gb-button-text\"><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong><strong>Which data logger supports SDI-12 sensors for environmental monitoring?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-24d3af38\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-24d3af38\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin, in its 100 and 200 models, features an SDI-12 sensor bus. This allows digital environmental sensors\u2014such as those for soil moisture, water levels, or weather data\u2014to be connected directly and recorded together with analog measurements in a single device.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-bc17fe93 gb-accordion\">\n<div class=\"gb-container gb-container-a2840c46 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-420e0379 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-420e0379\"><span class=\"gb-button-text\"><strong>How does a data logger count rapid pulses and frequencies?<\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-dafc03fd\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-dafc03fd\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin offers digital\/frequency inputs up to 1 MHz with 64-bit counters. This allows flow, energy, and speed pulses to be recorded over long periods of time without the risk of overflow. The inputs are galvanically isolated from PE and from each other at \u00b1400 VDC.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-b3352528 gb-accordion\">\n<div class=\"gb-container gb-container-85c25460 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-005a4309 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-005a4309\"><span class=\"gb-button-text\"><strong><strong>Why should the measurement channels of a data logger be electrically isolated?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-1c8b39ab\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-1c8b39ab\">\n\n<p class=\"wp-block-paragraph\">Galvanic isolation prevents ground loops and increases operational safety. In the Delphin Expert Logger, the channels are isolated from PE and from each other\u2014with an isolation voltage of \u00b1400 VDC and a dielectric strength of \u00b1110 VDC. This effectively prevents interference between different potentials.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-a9ec55de gb-accordion\">\n<div class=\"gb-container gb-container-185e8173 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-e26c32a9 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-e26c32a9\"><span class=\"gb-button-text\"><strong><strong>Which data logger can not only measure signals but also output them?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-1ec220f4\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-1ec220f4\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger Type 400 from Delphin features six analog outputs with 16-bit resolution and output ranges from 0 to 10 V and 0 to 20 mA, respectively. Supplemented by 24 digital inputs\/outputs and PWM signals (5 Hz to 10 kHz), it is suitable for control and regulation tasks on test benches.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-a7522342 gb-accordion\">\n<div class=\"gb-container gb-container-ba892ef4 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-144d2964 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-144d2964\"><span class=\"gb-button-text\"><strong><strong>How much internal memory does a data logger have, and can it be expanded?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-0161c549\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-0161c549\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin features 32 GB of internal memory for up to 960 million data points\u2014including date and millisecond-level timestamps. Storage can be flexibly expanded via USB media, network storage (NAS with NFS or CIFS), and (S)FTP.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-bdb51fdf gb-accordion\">\n<div class=\"gb-container gb-container-3e9c7c51 gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3eab9bd0 gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-3eab9bd0\"><span class=\"gb-button-text\"><strong><strong>Can a data logger record data on an event-driven basis rather than continuously?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-cdd28472\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-cdd28472\">\n\n<p class=\"wp-block-paragraph\">Yes\u2014the Expert Logger from Delphin records measurement data either on a time-based or event-based schedule, including both preceding and subsequent data in each case. This ensures that only relevant process segments are stored, which saves storage space and significantly simplifies the subsequent analysis of fault events.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-f5e6b473 gb-accordion\">\n<div class=\"gb-container gb-container-f0cb966d gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-de4defbc gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-de4defbc\"><span class=\"gb-button-text\"><strong><strong>How does a data logger automatically transmit measurement data to a higher-level system?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-002fe96b\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-002fe96b\">\n\n<p class=\"wp-block-paragraph\">The Expert Logger from Delphin automatically transmits measurement data to the Internet or to external storage devices via the PUSH function. In addition, network protocols, open APIs, and direct integration with IT and automation systems are available. Event-triggered transmissions with pre- and post-data are also possible.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-container gb-container-ca03a452 gb-accordion\">\n<div class=\"gb-container gb-container-0577c28f gb-accordion__item gb-accordion__item-open\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-b1fbe58e gb-accordion__toggle gb-block-is-current\" id=\"gb-accordion-toggle-b1fbe58e\"><span class=\"gb-button-text\"><strong><strong>Can a data logger automatically trigger an alarm if a threshold is exceeded?<\/strong><\/strong><\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" aria-hidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-3fe11ab3\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-3fe11ab3\">\n\n<p class=\"wp-block-paragraph\">Yes\u2014the Expert Logger from Delphin monitors threshold values directly within the device and, when necessary, triggers digital outputs or automatic notifications via email and SMS. Since the monitoring runs within the device, the alarm system functions even without a running PC or a higher-level control system.<\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<\/div><\/div>\n\n<div id=\"technische-daten\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Technical specifications<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-908ba896 gb-container-00a24a60\">\n<div class=\"gb-container gb-container-f1836c22 del-accordion-preview gb-accordion\">\n<div class=\"gb-container gb-container-fe4b4821 gb-accordion__item\" data-transition=\"slide\">\n\n<button class=\"gb-button gb-button-3c1e3b88 gb-accordion__toggle\" id=\"gb-accordion-toggle-3c1e3b88\"><span class=\"gb-button-text\">All data overview<\/span><span class=\"gb-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" ariahidden=\"true\" role=\"img\" class=\"gb-accordion__icon\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\" fill=\"currentColor\"><\/path><\/svg><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" width=\"1em\" height=\"1em\" ariahidden=\"true\" role=\"img\" class=\"gb-accordion__icon-open\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\" fill=\"currentColor\"><\/path><\/svg><\/span><\/button>\n\n\n<div id=\"gb-accordion-content-8b8b1a0d\" class=\"gb-accordion__content\"><div class=\"gb-container gb-container-8b8b1a0d\">\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Expert Logger device type<\/strong><\/td><td><strong>100<\/strong><\/td><td><strong>200<\/strong><\/td><td><strong>300<\/strong><\/td><td><strong>400<\/strong><\/td><\/tr><tr><td><strong>Analog inputs (mV, mA, TC)<\/strong><\/td><td><strong>16<\/strong><\/td><td><strong>32<\/strong><\/td><td><strong>46<\/strong><\/td><td><strong>16<\/strong><\/td><\/tr><tr><td>Appropriate for RTD's<\/td><td>8<\/td><td>16<\/td><td>23<\/td><td>8<\/td><\/tr><tr><td>Total sampling rate<\/td><td>1000 Hz<\/td><td>2 groups<br>\u00e0 1000 Hz<\/td><td>3 groups<br>\u00e0 1000 Hz<\/td><td>1000 Hz<\/td><\/tr><tr><td>Voltage measurement range<\/td><td colspan=\"4\">\u00b1156 mV .. \u00b110 V&nbsp;<\/td><\/tr><tr><td>Current measuring range<\/td><td colspan=\"4\">0 .. 20 mA, 4 .. 20 mA, free<\/td><\/tr><tr><td>Current reference for restistance measurement<\/td><td colspan=\"4\">100 \u03bcA, 200 \u03bcA or 1 mA (4-wire); 2 x 200 \u00b5A (3-wire)<\/td><\/tr><tr><td>Resistance measurement range<\/td><td colspan=\"4\">0 .. 100 k\u03a9<\/td><\/tr><tr><td>Resolution\/type ADC \/ input impedance<\/td><td colspan=\"4\">24 bit Sigma-Delta \/ 1G\u03a9<\/td><\/tr><tr><td>Internal reference junctions<\/td><td>yes \/ 2<\/td><td>yes \/ 4<\/td><td>yes \/ 6<\/td><td>yes \/ 2<\/td><\/tr><tr><td class=\"translation-block\">Withstand voltage \/ galvanic isolation<\/td><td colspan=\"4\">\u00b1110 VDC \/ \u00b1 400 VDC to PE, other channel group<\/td><\/tr><tr><td>Measuring accuracy voltage, current<\/td><td colspan=\"4\">0.01% from upper range value<\/td><\/tr><tr><td>Measuring accuracy resistance measurement<\/td><td colspan=\"4\">0.02% of the measuring range end value (4-wire connection)<\/td><\/tr><tr><td>Measuring accuracy thermocouples*<\/td><td colspan=\"4\">External thermoblock: 0.3 K<br>Internal reference measuring point: 0.1 % of the measuring range after sensor compensation<\/td><\/tr><tr><td><strong>Measuring accuracy Pt 100 <\/strong>(4-wire connection)<\/td><td colspan=\"4\">Measuring range -260 \u00b0C to 147 \u00b0C: 0.10 \u00b0C<br>Measuring range -260 \u00b0C to 596 \u00b0C: 0.20 \u00b0C<br>Measuring range -260 \u00b0C to 849 \u00b0C: 0.43 \u00b0C<\/td><\/tr><tr><td><strong>Measuring accuracy Pt 1000 <\/strong>(4-wire connection)<\/td><td colspan=\"4\">Measuring range -260 \u00b0C to 64 \u00b0C: 0.10 \u00b0C<br>Measuring range -260 \u00b0C to 408 \u00b0C: 0.15 \u00b0C<br>Measuring range -260 \u00b0C to 849 \u00b0C: 0.35\u00b0C<\/td><\/tr><tr><td><strong>Strain gauge voltage excitation<\/strong><\/td><td><strong>1<\/strong><\/td><td><strong>1<\/strong><\/td><td><strong>0<\/strong><\/td><td><strong>0<\/strong><\/td><\/tr><tr><td>Voltage<\/td><td colspan=\"4\">internal: 5 VDC \u00b1 10 mV, external: 1 \/ 2.5 \/ 5 \/ 10 V<\/td><\/tr><tr><td><strong>Analog outputs<\/strong><\/td><td><strong>0<\/strong><\/td><td><strong>0<\/strong><\/td><td><strong>0<\/strong><\/td><td><strong>6<\/strong><\/td><\/tr><tr><td>Resolution<\/td><td colspan=\"4\">16 bit<\/td><\/tr><tr><td>Output ranges<\/td><td colspan=\"4\">0 .. 10 V \/ \u00b1 10 V \/ 0 ... 5 V \/ \u00b1 5 V \/ 0 ... 12 V \/ \u00b1 12 V \/ 0 ... 6 V \/ \u00b1 6 V \/ 0 ... 20 mA \/ 0 ... 24 mA \/ 4 ... 20 mA \/<\/td><\/tr><tr><td>Galvanic isolation<\/td><td colspan=\"4\">\u00b1 400 VDC to system \/ PE<\/td><\/tr><tr><td>Min. load \/ max. burden<\/td><td colspan=\"4\">625 \u03a9 \/ 950 \u03a9<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-small-font-size\"><em>* These measuring accuracies apply to positive measuring temperatures (&gt; 0\u00b0C). For measurements in the negative temperature range, we recommend calibration at the respective operating point.<\/em><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Expert Logger device type<\/strong><\/td><td><strong>100<\/strong><\/td><td><strong>200<\/strong><\/td><td><strong>300<\/strong><\/td><td><strong>400<\/strong><\/td><\/tr><tr><td><strong>Number of digital channels<\/strong><\/td><td colspan=\"4\">&nbsp;<\/td><\/tr><tr><td>Digital inputs up to 1 MHz<\/td><td>3<\/td><td>3<\/td><td>0<\/td><td>0<\/td><\/tr><tr><td>Digital inputs up to 250 Hz<\/td><td>1<\/td><td>1<\/td><td>0<\/td><td>1<\/td><\/tr><tr><td>Digital outputs<\/td><td>4<\/td><td>4<\/td><td>0<\/td><td>0<\/td><\/tr><tr><td>Digital inputs \/ outputs<\/td><td>4<\/td><td>4<\/td><td>1<\/td><td>24<\/td><\/tr><tr><td><strong>Technical information digital inputs<\/strong><\/td><td colspan=\"4\">&nbsp;<\/td><\/tr><tr><td>Input signal<\/td><td colspan=\"4\">low: 0 .. 1 V\/ high:5 .. 100 VDC@3.5 mA<\/td><\/tr><tr><td>Frequency range \/ width counter<\/td><td colspan=\"4\">0,2 Hz .. 1 MHz, respectively 0,2 Hz .. 250 Hz \/ 64 bit<\/td><\/tr><tr><td>Galvanic isolation<\/td><td colspan=\"4\">\u00b1 400 VDC to PE \/ other channels<\/td><\/tr><tr><td><strong>Technical information digital outputs<\/strong><\/td><td colspan=\"4\">&nbsp;<\/td><\/tr><tr><td>Max. switching voltage \/ current<\/td><td colspan=\"4\">50 V \/ 2.5 A for 2 seconds, 250 mA continuous current<\/td><\/tr><tr><td>PWM function \/ pulse duty factor<\/td><td colspan=\"4\">Basic frequency 5 Hz .. 10 kHz \/ 1:1000<\/td><\/tr><tr><td>Galvanic isolation<\/td><td colspan=\"4\">\u00b1 400 VDC to PE \/ other channels<\/td><\/tr><tr><td><strong>Data storage<\/strong><\/td><td colspan=\"4\">&nbsp;<\/td><\/tr><tr><td>Data storage internal<\/td><td colspan=\"4\">32 GB (approx. 960 million measured values)<\/td><\/tr><tr><td>Data storage external<\/td><td colspan=\"4\">USB, NFS, CIFS, (S)FTP<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Expert Logger device type<\/strong><\/td><td><strong>100<\/strong><\/td><td><strong>200<\/strong><\/td><td><strong>300<\/strong><\/td><td><strong>400<\/strong><\/td><\/tr><tr><td><strong>Interfaces \/ protocols<\/strong><\/td><td colspan=\"4\">&nbsp;<\/td><\/tr><tr><td>SDI 12 sensor bus<\/td><td>1<\/td><td>1<\/td><td>0<\/td><td>0<\/td><\/tr><tr><td>COM1 and COM 2<\/td><td colspan=\"4\">RS485, 9-pin Sub-D socket \/ ASCII, SCPI, Modbus RTU Master &amp; Slave, PROFIBUS DPV1 Slave with sniffer function<\/td><\/tr><tr><td>COM 3<\/td><td colspan=\"4\">RS232, 9-pole sub-D plug \/ ASCII \/ SCPI \/ Modbus RTU<\/td><\/tr><tr><td>LAN<\/td><td colspan=\"4\">1 x 1000BASE-T<\/td><\/tr><tr><td>USB<\/td><td colspan=\"4\">Device 2.0 \/ Host 2.0 low \/ high \/ full<\/td><\/tr><tr><td>TCP \/ IP<\/td><td colspan=\"4\">Modbus TCP Server &amp; Client, OPC UA Server &amp; Client, OPC UA HA Server (optional)<\/td><\/tr><tr><td>PROFINET (TCP\/IP)<\/td><td colspan=\"4\">PROFINET RT Device, IO\/MRP\/LLDP, Conf Class B, RT Class 1, Netload Class III, I&amp;M 0,1,2,3,5, 2xRJ45 100MBit\/s full duplex<\/td><\/tr><tr><td>CAN \/ RS 232\/485<\/td><td colspan=\"4\">2 x CAN 2.0 \/ Modbus RTU Master &amp; Slave, SCPI, ASCII, SMTP, NTP, PTP<\/td><\/tr><tr><td><strong>General technical information<\/strong><\/td><td colspan=\"4\">&nbsp;<\/td><\/tr><tr><td>Dimensions \/ weight<\/td><td colspan=\"4\">W 217 mm x H 88 mm x D 128 mm \/ 750 g<\/td><\/tr><tr><td>Fixing<\/td><td colspan=\"4\">Mounting rail DIN EN 60715 or screw mounting<\/td><\/tr><tr><td>Connecting terminals<\/td><td colspan=\"4\">Plug-in screw terminals, 96 terminals in 2 rows, max. 1.5 mm\u00b2<\/td><\/tr><tr><td>Temperature range<\/td><td colspan=\"4\">-20 .. 50 \u00b0C*<\/td><\/tr><tr><td>Humidity<\/td><td colspan=\"4\">max. 90 % relative humidity, non-condensing<\/td><\/tr><tr><td>Supply voltage<\/td><td colspan=\"4\">12 .. 24 V \/ \u00b1 10%<\/td><\/tr><tr><td>Power input normal mode<\/td><td colspan=\"4\">max. 15 watts<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">* Sufficient air circulation in the control cabinet must be ensured.<br><em>Status: 20.02.2025<\/em><\/p>\n\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div id=\"software\" class=\"delphin-produkt-trenner-block\">\n\n    \n    \n    <div class=\"trenner-block__bg-1\" >\n        <h2 class='trenner-block__titel'>Software<\/h2>\n    <\/div>\n    <div class=\"trenner-block__bg-2\" ><\/div>\n    \n<\/div>\n\n<div class=\"gb-container gb-container-41fd161a gb-container-00a24a60\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">Software interfaces<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern software interfaces make Expert Logger compatible with common industrial and IoT systems.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"delphin-softio grid-3x1\"><div class=\"softio-box softio-interfaces\" style=\"--box-bg:#FFFFFF;\"><h3 class=\"softio-title\">Interfaces<\/h3><div class=\"softio-content\"><ul>\n<li>OPC (Server\/Client)<\/li>\n<li>OPC UA (Server\/Client)<\/li>\n<li>OPC UA HA (Server)<\/li>\n<li>API<\/li>\n<li>Python<\/li>\n<li>SQL<\/li>\n<li>LabView<\/li>\n<li>Diadem<\/li>\n<li>Modbus TCP<\/li>\n<li>DasyLab<\/li>\n<\/ul>\n<\/div><\/div><div class=\"softio-box softio-dataservice\" style=\"--box-bg:#FFFFFF;\"><h3 class=\"softio-title\">DataService \/ Data Center<\/h3><\/div><div class=\"softio-hero\" style=\"--box-bg:#FFFFFF;\"><h2 class=\"softio-main-title\">Expert Logger<\/h2><figure class=\"softio-figure\"><img decoding=\"async\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/20250108_Expert_Logger_2-1024x484.png\" alt=\"Expert Logger Hardware\" title=\"\"><\/figure><\/div><\/section>\n<\/div><\/div>\n\n<div class=\"gb-container gb-container-175b5a02\"><div class=\"gb-inside-container\">\n\n<h2 class=\"wp-block-heading\">Suitable software for Expert Logger<\/h2>\n\n\n<div class=\"produkt-tabs-block\" style=\"\">\n    <div class=\"produkt-tabs__container\"><div class=\"produkt-tabs\"><div class='produkt-tab activeTab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-go-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Go<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-basic-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Basic<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-klicks-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal Klicks<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/04\/delphin-profisignal-20-basic-230427.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal 20 Basic<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"240\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-300x240.png\" class=\"produkt-tab__img\" alt=\"\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-300x240.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426-768x613.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/profisignal-20-go-230426.png 1002w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>ProfiSignal 20 Go<\/div><\/div><div class='produkt-tab'><img decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-300x225.png\" class=\"produkt-tab__img\" alt=\"Central measurement data management Delphin Date Canter\" srcset=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-300x225.png 300w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-768x576.png 768w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025-16x12.png 16w, https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/Delphin_DDC_ProduktTabs_2025.png 987w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"\"><div class='produkt-tab__titel'>Delphin Data Center<\/div><\/div><\/div><\/div><div class=\"produkt-details\"><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Go<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Data acquisition and analysis<\/h3><p class='produkt-detail__text'>Display and monitor measurement data live | Intuitive operation and easy handling without programming knowledge | Versatile diagram and analysis functions for various measurement data | Ready for data acquisition and analysis in just a few minutes<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-go\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-go-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Basic<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Operating and monitoring<\/h3><p class='produkt-detail__text'>Reliably record and save measurement data | Clearly display and evaluate measured values | Quickly set up and operate projects without programming effort | Ideal for individual measuring stations up to small measuring systems<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-basic\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-basic-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal Klicks<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Automate and control<\/h3><p class='produkt-detail__text'>Monitor measurement data and control processes directly | Create automations simply by dragging and dropping | Suitable for complex test benches and automation tasks | Implement and adapt projects without programming knowledge<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal\/profisignal-klicks\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal-klicks-230418-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal 20 Basic<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Visualisation and operation<\/h3><p class='produkt-detail__text'>Easily create your own visualizations for measurement data | Conveniently evaluate and log measurement and process data | Intuitive interface for efficient work without programming knowledge | Ideal for individual measuring stations through to complex monitoring solutions<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal-20\/profisignal-20-basic\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal20-basic-230329-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>ProfiSignal 20 Go<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Data acquisition and saving<\/h3><p class='produkt-detail__text'>Display and monitor signals and processes in real time | Easy handling with no training required | Access to measurement data from PC, tablet or smartphone | Ready for many measurement and analysis tasks in just a few minutes<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/profisignal-20\/profisignal-20-go\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-profisignal20-go-230329-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><div class=\"produkt-detail\"><div class=\"produkt-detail__inner\"><div class=\"produkt-detail__col1\"><div class='produkt-detail__produkt-titel gb-headline gb-headline-text gb-headline-topline'>Delphin Data Center<\/div><h3 class='produkt-detail__ueberschrift gb-headline gb-headline-text gb-headline-h2'>Central measurement data management<\/h3><p class='produkt-detail__text'>Central storage of operating, maintenance and process data | Cross-site real-time monitoring of machine and process statuses | Modular structure makes it easy to adapt to growing plant and process environments<\/p><a href=\"https:\/\/www.delphin.de\/en\/produkte\/messtechnik-software\/delphin-data-center\/\" class=\"produkt-detail__button gb-button gb-button-text gb-button-standard\">To the product<\/a><\/div><div class=\"produkt-detail__col2\"><img decoding=\"async\" class=\"produkt-detail__img\" src=\"https:\/\/www.delphin.de\/wp-content\/uploads\/2023\/03\/delphin-beitragsbild-ddc-230329-1-1024x831.jpg\" alt=\"\" title=\"\"><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div>\n\n<div class=\"gb-container gb-container-c0f069fe gb-container-00a24a60\">\n\n<h2 class=\"wp-block-heading\">Software channels as extended functions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Realise and execute monitoring and automation tasks easily<\/strong>&nbsp;<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Our measuring and testing devices have extended functions, which are summarized under the term software channels. The online measurement data is offset against the software channels and then used for visualization, storage or control.\u00a0\u00a0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this way, entire programme sequences can be configured very simply and intuitively with the regulation and control function. These then run autonomously without PC support. This is how you use your data logger effectively, also as a monitoring device or PLC replacement.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The software channels enable functions such as limit value monitoring, integration or online calculation and are configured very easily. This means that even users who are not experts in programming can easily implement their own monitoring tasks or balancing independently in the unit.&nbsp;<\/p>\n\n\n\n<a class=\"gb-button gb-button-e5af81a4 gb-button-text gb-button-small\" href=\"https:\/\/www.delphin.de\/en\/products\/measurement-software\/software-channels\/\" target=\"_blank\" rel=\"noopener noreferrer\">More information<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Precisely record, autonomously store, automatically transmit and evaluate measured values.<\/p>","protected":false},"author":1,"featured_media":15645,"parent":1168,"menu_order":1,"template":"","format":"standard","categories":[1],"tags":[],"class_list":["post-939","produkt","type-produkt","status-publish","format-standard","has-post-thumbnail","hentry","category-hardware"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/types\/produkt"}],"author":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":45,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/939\/revisions"}],"predecessor-version":[{"id":18344,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/939\/revisions\/18344"}],"up":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/produkt\/1168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media\/15645"}],"wp:attachment":[{"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/media?parent=939"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/categories?post=939"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.delphin.de\/en\/wp-json\/wp\/v2\/tags?post=939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}