Interfaces in Measurement Technology

With interfaces ranging from the sensor all the way to IT—Seamlessly connected

Delphin connects sensors, PLCs, analyzers, scales, and third-party systems via Modbus, PROFIBUS, PROFINET, RS232/RS485, OPC UA, MQTT, SQL/ODBC, and open APIs to form a unified, time-synchronized database. Measurement data acquisition runs autonomously within the Delphin hardware, while the Delphin Data Center (DDC) makes the data available in a controlled manner for OT, IT, and proprietary applications.

The Most Important Points at a Glance

All common protocols
Modbus TCP/RTU, PROFIBUS, PROFINET, RS232, RS485, ASCII, OPC UA / OPC UA HA, MQTT, SQL/ODBC, and APIs for Python, C/C++, C#, and LabVIEW.

Two options that can be freely combined
Connection directly via the machine's hardware or via software through the Delphin Data Center at the PC or server level.

No data gaps
The devices continue to take measurements even during network, PC, or server outages and automatically fill in any missing data once the connection is restored.

OT and IT are clearly separated
The DDC is the controlled interface layer: IT does not access individual measuring devices directly.

New: MQTT and JSON parsers
With Release 26.2, the DDC connects IoT and IIoT data via MQTT—JSON messages are automatically broken down into channels.

Configure Instead of Program
Data points are selected, mapped, and transferred to other systems in the configurator—without the need for custom programming.

Why Interfaces Are Becoming a Challenge in Industry

In established plants, data is generated everywhere: from sensors, PLCs, analyzers, scales, energy meters, and third-party systems. Each source uses its own protocols, data formats, and timestamps - often on separate computers running different versions of Windows.

This results in manual steps, scattered files, and Excel spreadsheets that must be synchronized afterward. Maintenance and modernization become time - consuming.

Objective: To consolidate and synchronize heterogeneous system environments.

  • Many unconnected data sources in a facility
  • Various Protocols and Data Formats
  • Non-synchronous timestamps
  • Several individual programs for operating the device
  • Data is to be collected, stored, and shared

The Delphin Complete Solution: Hardware and Delphin Data Center (DDC)

What is the Delphin Data Center? The Delphin Data Center (DDC) is Delphin’s central communications and data platform. It consolidates measurement data from various plants, devices, and third-party systems, stores it centrally, and makes it available in a structured format for ERP, reporting, visualization, cloud applications, and in-house applications. The DDC runs on a PC or server - either online on the network or offline without a cloud connection.

  • Direct Communication with Field Devices and Third-Party Devices
  • Processing of Analog Signals and Field Protocols at the Machine
  • Independent of a PC or server (Edge)
  • Calculation Channels for Threshold Values, Min/Max, and Control Functions
  • Data Access and Provision via the DDC
  • Integrate third-party systems directly via APIs and databases
  • Centralized Communication at the Server or PC Level
  • Scalable from a single system to a centralized architecture

Both can be flexibly combined: The task determines where communication takes place most effectively.

Fail-safe measurement: autonomous data collection and seamless updating

Delphin measurement devices such as Expert Logger, Expert Vibro, ProfiMessage D, and Loggito collect and store measurement data locally - without relying on a network, PC, or server. If the central infrastructure fails, measurement continues. After a power outage, the devices automatically resume data collection.

Additional storage areas can be used as redundancy for critical measurement data. The data is available as a database or as a CSV or ASCII file for analysis and visualization. Remote access for maintenance and support, as well as SSL-encrypted connections with certificates, are supported.

  1. Network Outage: The ongoing measurement is not affected.
  2. Local recording: Measurement data continues to be recorded in the device's memory.
  3. Reconnection: The device reconnects to the DDC.
  4. Tracking: Missing data is filled in automatically or manually - ensuring a complete history of measurement data.

Connecting OT and IT – Keeping System Environments Clearly Separated

Using a second network interface, the DDC separates the field level (OT) from the IT level. Measurement devices and test stands remain isolated within the OT network, while ERP, reporting, cloud, and visualization systems access the provided data in a controlled manner.

OT · FIELD LEVEL

Machines, PLCs, measuring instruments, test stands, and process data

DELPHIN DATA CENTER

Controlled data provision and a central interface layer - no direct IT access to individual measuring devices

IT · CORPORATE LEVEL

Databases, MES/ERP, reporting, analytics, and cloud and business systems

Which interface for which task?

It is not the interface that determines the application - rather, the application and the existing infrastructure determine the interface. Depending on the system, devices are connected directly, data is mapped, or protocols are transferred to other communication channels via a gateway.

InterfaceAvailable inTypical useApplication example
Modbus TCP / RTUHardware and DDCSimple, robust device communication with controllers, meters, and field devices - serial RTU, TCP over EthernetTest specimens send data via Modbus; the data logger checks Modbus and analog values in the processing channel for plausibility.
PROFIBUS / PROFINETHardwareDirect integration of measurement technology into PLC and automation environments, unidirectional and bidirectionalProcess data that the PLC uses solely for control purposes is logged, mapped, and reused.
RS232 / RS485 / ASCIIHardware and DDCIntegration of older or specialized devices such as analyzers, scales, controllers, and pumps; custom ASCII telegramsMultiple analyzers are read and operated within a single application rather than in multiple programs.
OPC UA / OPC UA HAHardware and DDCStandardized, platform-independent data exchange, including metadata; OPC UA HA for historical dataData points are browsed, and sensor readings are displayed directly in a cloud application.
MQTT + JSON Parser (New)DDCIoT, IIoT, and IT communication using the publish-subscribe model, unidirectional and bidirectionalIoT sensors send temperature and humidity data to the DDC via a broker.
SQL / ODBCHardware and DDCReading and writing to databases, integration into existing IT systems, reportingProcess data and unit counts are automatically documented and entered into the ERP system.
Open APIsDDCCustom applications in Python, C/C++, C#, or LabVIEW - without being tied to ProfiSignalAn existing application uses measurement data from new Delphin devices via the API.

MQTT and JSON-Paser in the Delphin Data Center

MQTT is a lightweight publish-subscribe protocol for IoT and IIoT. The DDC connects to an MQTT broker of your choice, subscribes to topics, publishes its own data, or forwards received values to other systems - and can even do so bidirectionally with compatible devices.

Since MQTT messages are usually transmitted in JSON format, the built-in JSON parser breaks down the structure into individual data points using a template and automatically creates channels and subchannels. Essentially, the only thing that needs to be added manually are the units.

Technical information

  • MQTT 3.1.1 and MQTT 5.0
  • DDC as a Subscriber and Publisher
  • Security via TLS, mTLS, and TLS-PSK
  • JSON data types: Float, Integer, String, Boolean
  • Initially available as a beta version

How to Set Up an MQTT Connection

  1. Create an MQTT client: broker address, port, client ID, and MQTT version
  2. Optionally, store security parameters and certificates
  3. Define MQTT inputs with a topic, data type, and a fallback value (if applicable)
  4. Select a JSON template - the parser automatically generates the channels

Frequently Asked Questions About Interfaces in Measurement Technology

What interfaces does Delphin support? Delphin supports Modbus TCP and RTU, PROFIBUS, PROFINET, RS232, RS485, ASCII protocols, OPC UA and OPC UA HA, MQTT 3.1.1 and 5.0, SQL/ODBC databases, and open APIs for Python, C/C++, C#, and LabVIEW. Depending on the protocol, the connection is established in the hardware, in the Delphin Data Center, or in both.

What is the difference between hardware-based and software-based connectivity? On the hardware side, the Delphin measuring device communicates directly with field devices and third-party devices on the machine and operates independently of a PC or server. On the software side, the Delphin Data Center handles communication centrally at the PC or server level. Both approaches can be combined.

What happens to measurement data in the event of a network or server failure? The Delphin devices continue to store measurement values locally. As soon as the connection to the DDC is restored, the missing data is backfilled, ensuring a complete measurement history.

Can older devices with a serial interface be integrated? Yes. Analyzers, scales, controllers, pumps, and specialized devices with RS232 or RS485 can be integrated. To do this, Delphin requires the device’s communication protocol and command set, which it uses to create a driver for the specific ASCII telegrams - for reading measured values and sending control commands.

How does the JSON parser work in the Delphin Data Center? The JSON parser interprets incoming MQTT messages in JSON format using a template, breaks them down into individual data points, and automatically creates channels and subchannels from them. The supported data types are float, integer, string, and boolean.

How does the DDC separate the OT and IT networks? The DDC can separate the field level from the IT level via a second network interface. IT systems access only the data provided by the DDC, not individual measuring devices directly.

Can Delphin devices be used as protocol gateways? Yes. Delphin devices can convert data between protocols, such as Modbus RTU to Modbus TCP, OPC UA, PROFIBUS, or PROFINET. The data points are mapped in the configurator without the need for individual programming.

Does the Delphin Data Center need a cloud connection? No. The DDC can be operated online on a network or completely offline without a cloud connection. Cloud applications can be integrated as needed via OPC UA, MQTT, databases, or APIs.

To the original article

PDF Download