Technical specifications - ProfiMessage

All data overview

Module type
(2 modules per master / slave)
ADVT / AAST / ADITADGTIOIT / OTPT / DIOT
Analog inputs15 / 4 / 108
Sensorsmv, mA, Thermocouples, RTD (RTD except ADVT)mv, mA, Thermocouples, RTD
Total sampling rate600 Hz60 Hz
Voltage and current measurement range156 mV .. 10 V, ± 156 mV .. ± 10 V / 0 .. 20 mA, 4 .. mA,
± 20 mA
 
Galvanic isolation to system750 VDC          400 VDC
Galvanic isolation channel to channel110 V          650 V
Resolution/Type ADC24 bit Sigma-Delta24 bit Sigma-Delta
Measurement accuracyVoltage, current: V / mA: 0.01 % of the measuring range end value
Thermocouples: 0.1 % of measuring range after sensor compensation*
Measuring accuracy Pt 100 (4-wire connection)Measuring range -260 °C to 147 °C: 0.10 °C
Measuring range -260 °C to 596 °C: 0.20 °C
Measuring range -260 °C to 849 °C: 0.43 °C
Measuring accuracy Pt 1000 (4-wire connection)Measuring range -260 °C to 64 °C: 0.10 °C
Measuring range -260 °C to 408 °C: 0.15 °C
Measuring range -260 °C to 849 °C: 0.35°C
Analog outputs– / 4 / 1
Resolution16 bit
Potential isolation750 V
Output0/4 .. 20 mA
Min. load / max. burden650 Ω

* These measuring accuracies apply to positive measuring temperatures (> 0°C). For measurements in the negative temperature range, we recommend calibration at the respective operating point.

Module type
(2 modules per master / slave)
ADVT / AAST / ADITADGTIOIT / OTPT / DIOT
Digital
inputs
– / 2 / –24 / 1 / 12
Thereof with frequency measurement / counting function– / – / –– / – / 11
Max. measurement frequency– / – / –- / - / 30 kHz
Input measurement rangelow: 0 .. 1.5 VDC@0 .. 1.5 mA / high: 3.5 .. 90 (ProfiLab: 50)
VDC@ 2.5 .. 3.5 mADC
Potential isolation2.5 kV
Digital outputs– / 2 / 11 / 24 / 16
Potential isolation2.5 kV
Switching voltagemax. 50 VDC@2.5 A
Data storage 
Internal0.5 .. 15.5 GB (approx. 30 million mesurement values per GB)
Module type
(2 modules per master / slave)
ADVT / AAST / ADITADGTIOIT / OTPT / DIOT
Interfaces 
Physical equipment
COM 1 / COM 2
RS485, 9-pole sub-D socket, IEC 61158-2
Physical equipment
COM 3 / COM 4
RS232, 9-pole sub-D-socket (COM 3), 9-pole sub-D plug (COM 4)
Protocols COM 1 / COM 2PROFIBUS DPV1 slave (both interfaces), also redundant according to PNO 2.212 V1.2
Protocols COM 1 .. COM 4Modbus RTU master / slave, customer-specific protocols, ASCII
TCP/IPRJ45 (8-pole STP-socket), 100Base-TX; Protocols: TCP/IP, HTTP, SMTP, NTP, Modbus TCP and OPC UA client / server
USBUSB 1.1 for data memory read out
CAN9-pole sub-D socket, Protocols: CAN, RAW; baud rates: 25 k .. 1 MBaud; dbc-import possible
Module bus 
Physical equipment3-pole Phoenix plug-in terminal; Internal bus for connecting further modules
Baud rate / length1 MBaud / 10 m .. 25 kBaud / 100m
General technical information 
ProfiMessage dimensions / weightW 200 x H 73 x D 122 mm / 1 kg
ProfiMessage mountingMounting rail DIN EN 60715 or screw mounting
ProfiMessage signal connectionsDetachable screw terminals, 33 terminals in 2 rows, lead protection,
connecting cabling max. 2.5 mm²
ProfiLab dimensionsW 226 x H 145 x D 180 mm
ProfiLab signal connectionsup to 64 pieces 4 mm laboratory sockets, gold-plated
Temperature range-20 .. 50 °C
Humiditymax. 90 % relative humidity, non-condensing
Supply voltage12 .. 36 VDC / 12 .. 28 VAC rms / ± 10 %
Power input< 10 watts

Status: 06.12.2023